Skip to main content
Advertisement
Browse Subject Areas
?

Click through the PLOS taxonomy to find articles in your field.

For more information about PLOS Subject Areas, click here.

  • Loading metrics

Assessing the value of complex refractive index and particle density for calibration of low-cost particle matter sensor for size-resolved particle count and PM2.5 measurements

  • Ching-Hsuan Huang,

    Roles Conceptualization, Data curation, Formal analysis, Methodology, Software, Visualization, Writing – original draft

    Affiliation Department of Environmental and Occupational Health Sciences, School of Public Health, University of Washington, Seattle, Washington, United States of America

  • Jiayang He,

    Roles Conceptualization, Methodology, Project administration, Resources, Validation, Writing – review & editing

    Affiliation Department of Mechanical Engineering, College of Engineering, University of Washington, Seattle, Washington, United States of America

  • Elena Austin,

    Roles Conceptualization, Methodology, Supervision, Validation, Writing – review & editing

    Affiliation Department of Environmental and Occupational Health Sciences, School of Public Health, University of Washington, Seattle, Washington, United States of America

  • Edmund Seto,

    Roles Conceptualization, Methodology, Resources, Supervision, Validation, Writing – review & editing

    Affiliation Department of Environmental and Occupational Health Sciences, School of Public Health, University of Washington, Seattle, Washington, United States of America

  • Igor Novosselov

    Roles Conceptualization, Funding acquisition, Methodology, Project administration, Resources, Supervision, Validation, Writing – review & editing

    ivn@uw.edu

    Affiliation Department of Mechanical Engineering, College of Engineering, University of Washington, Seattle, Washington, United States of America

Abstract

Low-cost optical scattering particulate matter (PM) sensors report total or size-specific particle counts and mass concentrations. The PM concentration and size are estimated by the original equipment manufacturer (OEM) proprietary algorithms, which have inherent limitations since particle scattering depends on particles’ properties such as size, shape, and complex index of refraction (CRI) as well as environmental parameters such as temperature and relative humidity (RH). As low-cost PM sensors are not able to resolve individual particles, there is a need to characterize and calibrate sensors’ performance under a controlled environment. Here, we present improved calibration algorithms for Plantower PMS A003 sensor for mass indices and size-resolved number concentration. An aerosol chamber experimental protocol was used to evaluate sensor-to-sensor data reproducibility. The calibration was performed using four polydisperse test aerosols. The particle size distribution OEM calibration for PMS A003 sensor did not agree with the reference single particle sizer measurements. For the number concentration calibration, the linear model without adjusting for the aerosol properties and environmental conditions yields an absolute error (NMAE) of ~ 4.0% compared to the reference instrument. The calibration models adjusted for particle CRI and density account for non-linearity in the OEM’s mass concentrations estimates with NMAE within 5.0%. The calibration algorithms developed in this study can be used in indoor air quality monitoring, occupational/industrial exposure assessments, or near-source monitoring scenarios where field calibration might be challenging.

Introduction

The direct measurement of time- and size-resolved particle matter (PM) concentrations is essential to health-related applications, such as exposure assessments and air quality (AQ) studies, but are challenging to implement at fine spatial and temporal scales. Human exposure to PM is associated with multiple adverse health effects, including cardiovascular disease, cardiopulmonary disease, and lung cancer [17]. Estimates show that approximately 3% of cardiopulmonary and 5% of lung cancer deaths are attributed to exposures to PM2.5 (particles less than 2.5 μm in diameter) globally [8]. Particle deposition in the human respiratory tract and the resultant adverse health effects depend on the particles’ size distribution [9, 10]. PM concentration varies significantly in space and time across community settings [11, 12]. Hence, time- and size-resolved PM measurements are more informative than traditional total PM weight measurements for assessing adverse health effects. As part of the Clean Air Act, the National Ambient Air Quality Standard (NAAQS) set by the U.S. Environmental Protection Agency (EPA) has adopted and established monitoring requirements for six criteria air pollutants, including PM2.5 and PM10 [13, 14]. However, the sparse spatial distribution of government monitoring sites makes fine spatial scale exposure assessment challenging [8]. Traditional PM measurement instruments are large and expensive, thus have limited use in high spatial and temporal resolution mapping applications; these applications instead demand compact, low-cost sensors with reliable performance.

Low-cost PM sensors find increasing use in various applications, including monitoring AQ in the outdoor [1518] and indoor environment [1921] by academic researchers and citizen scientists. The low-cost sensor networks have the potential to provide high spatial and temporal and resolution, identifying pollution sources and hotspots, which in turn can lead to the development of intervention strategies for exposure assessment and intervention strategies for susceptible individuals. Time-resolved exposure data from wearable monitors can be used to assess individual exposure in near real-time [22].

As low-cost sensors find applications in pollution monitoring, and there is a need to characterize and calibrate their performance under various conditions, calibration in controlled environments with standardized test aerosols can provide the basis for such assessments. Various studies have evaluated the performance of low-cost PM sensors in laboratory and field settings [2330]; these reports show that low-cost sensors yield usable data when calibrated against research-grade reference instruments, although some drawbacks have been reported. One common concern is that calibrations for number concentrations have not been reported, and the mass concentration of the low-cost PM sensors is based on numerous assumptions. Second, there is a lack of information on low-cost sensors’ ability to assess particle size distributions, which is critical for assessing health and environmental impacts. Third, calibrations based on short-term field colocations with reference instruments are often limited by the range of particle properties, concentrations, and environmental conditions and thus cannot be generalized to other studies. This is a concern because with improving air quality in the developed nations, the typical PM2.5 levels are relatively low (<20 μg/m3); however, PM concentration during wildfires [31] and in occupational settings [32, 33] often exceeds regulatory limits for short periods. In developing countries with less strict regulations, the PM level associated with, e.g., traffic emissions [34], agricultural waste burning [35], indoor cooking [36] is significantly higher. In these settings, field colocations with reference instruments required for calibration studies can be challenging. Thus, evaluating low-cost PM sensors’ performance under high and low loading conditions is necessary if the sensors were to be used in epidemiological studies and PM surveillance networks.

Low-cost optical PM sensors rely on elastic light scattering to measure time- and size-resolved PM concentrations; they are widely used in aerosol research, particularly when measuring particles in the 0.5 μm to 10 μm range. Aerosol photometers that measure the bulk light scatter of multiple particles simultaneously have limited success in measuring mass concentration [30]. Typical low-cost (<$100) particle monitors often yield unreliable number concentrations data [37], but PM mass estimation error can be as high as 1000% [38]. Also, low-cost sensor measurements may suffer from sensor-to-sensor variability due to a lack of quality control and differences between individual components [30, 37]. Sensor geometry can be optimized to reduce the effect of particle CRI. Researchers have addressed CRI sensitivity by designing optical particle sizers (OPSs) that measure scattered light at multiple different angles simultaneously [39] or by employing dual-wavelength techniques [40]. However, these solutions involve complex and expensive components not suitable for compact, low-cost devices. Optimizing the detector angle relative to the excitation beam can reduce dependency on CRI [41]; however, this approach has not been translated to high volume production.

Some commercially available low-cost sensors provide output in total particle counts or particle mass concentrations, and some provide size-specific counts or mass concentrations. These quantities are not measured directly as an individual particle’s scattering signature (as in the single particle counters) but are estimated by the OEM proprietary algorithms. These algorithms have inherent limitations because particle scattering depends on the particles’ composition, size, shape, and CRI [42]. A common workaround is to collect PM on a filter after or in parallel with the OPS measurements. The filters are analyzed to determine their average particle optical properties; these data are then used to correct the optical measurements after the fact.

Environmental conditions can affect sensor output, e.g., a non-linear response has been reported with increasing RH [4347]. High humidity (RH > 75%) creates challenges for particle instruments; e.g., significant variations were observed between different commercially available instruments, such as Nova PM sensor [43] and personal DataRAM [45]. In addition, the RH measurement approach could also affect the sensor output [43, 44], e.g., the RH measurement based on reference monitoring site rather than inside the sensor enclosure may be different due to the microenvironment and transient effects. The selection of reference instruments with different measuring principles may also influence the calibration of low-cost sensors. For example, the calibration of the Plantower PM sensor in Jayaratne et al., 2018 was based on the tapered element oscillating microbalance (TEOM), while Zusman et al., 2020 calibrated the same sensor against the beta attenuation monitor (BAM) and federal reference method (FRM) measurements [29, 44]. The integrated mass measurements cannot account for temporal particle size and concentration variation during the calibration experiment. The instruments that directly measure aerosol size and concentration can be a better fit for sensor calibration [30, 48]. The calibration against aerodynamic particle sizer (APS) or single optical particle counter instruments can potentially provide a more robust calibration for low-cost optical particle sensors. Correlating particle diameter measured low-cost sensor to aerodynamic diameter measured by an APS is relevant since the aerodynamic diameter determines particle deposition in the respiratory tract.

This study presents calibration for PMS A003 (Beijing Plantower Co., Ltd, China; referred to as PMS hereafter) sensors as a function of particle sizes and concentration, as well as the PM2.5 and PM1 indices. The calibration is based on four polydisperse standard testing aerosols, including the Arizona Test Dust (ATD), two types of ceramic particles, and NaCl particles. The PMS data from six sensors were calibrated against the APS for particle size range 0.5–10 μm and number concentration in the range of 0–1000 #/cc. A standardized laboratory experimental protocol was developed to control the PM concentration, environmental conditions and to assess sensor-to-sensor reproducibility.

Materials and methods

Plantower PMS A003 and sensor test platform

The low-cost sensor PMS A003 was evaluated. The sensor’s photodiode is positioned perpendicular to the excitation beam and measures the ensemble scattering of particles in the optical volume. The scattering light intensity is then converted to a voltage signal to estimate PM number density and mass concentration using a proprietary calibration algorithm. The PMS provides estimated particle counts in six size bins with the optical diameter in 0.3–10 μm (#/0.1L) range and mass concentration (μg/m3) for PM1, PM2.5, and PM10. The mass concentrations are reported for two settings: "factory" and "atmospheric" conditions. The factory condition applies a correction factor (CF) of unity to the concentration measured, whereas the "atmospheric" condition is designed for use in the ambient environment.

Six PMS units were installed on a custom printed circuit board (PCB), which also included a Bosch BME680 temperature and relative humidity (RH) sensor (Fig 1). All sensors were connected to an Arduino Nano microcontroller through a data selector (multiplexer NXP 74HC4051 breakout board, Sparkfun, Boulder, CO). The controller collects data from the six PMS sensors and an RH and temperature sensor simultaneously with the data acquisition rate of 1 Hz. The data reported in "factory" mode were used in the analysis.

thumbnail
Fig 1. Photograph test platform, consisting of six PMS units mounted on the PCB, a temperature and humidity sensor, a multiplexer, and an Arduino microcontroller.

https://doi.org/10.1371/journal.pone.0259745.g001

The reference instrument used in this study is the TSI Aerodynamic Particle Sizer (APS) 3321 spectrometer. APS measures both the aerodynamic size and optical size of a particle. Using the time-of-flight principle, the APS measures size-resolved particle counts with aerodynamic particle diameter (AD) of 0.523 to 20 μm in 52 size bins. The lower detection limit for optical size is 0.37 μm. The APS’s optical sensor detects particles with AD<0.523 μm, but they can not be resolved based on their aerodynamic size. Thus these particles are assigned to a single bin <0.523 μm. The aerodynamic size determined the particle’s aerodynamic behavior, such as settling velocity or penetration into the respiratory tract. Thus, we evaluate the correlation between the PMS number concentrations and the APS aerodynamic size bin number concentrations. The instrument estimates mass concentration by assuming spherical particles and particle density input. APS reports particle concentrations with a 5-second resolution. In the experiments, the sampling inlet was placed near the PMS sensors. Per APS specifications, the maximum recommended particle concentration is 1000 #/cm3 at 0.5 μm with < 5% coincidence. Therefore, the total number concentration of the aerosols in the test chamber was maintained below 1000 #/cc (105 #/0.1L).

Aerosol chamber tests

We tested four polydisperse aerosols: Arizona Test Dust (ATD) (Powder Technology Incorporated, Arden Hills, MN), polydisperse W210, and W410 ceramic particles (3M™, St. Paul, MN), and sodium chloride (NaCl) particles. NaCl particles were generated by nebulizing the aqueous solution of 10% wt [49]. The challenge aerosols’ properties and typical size distributions are summarized in Table 1 and S3 Fig., respectively. The experiments were conducted in a custom-built aerosol chamber (0.56 m × 0.52 m × 0.42 m) (Fig 2). A full description of the chamber can be found in ref [50]. The PMS sensor platform was placed in the well-mixed aerosol test chamber, elevated to the same height as the APS inlet. The APS sampled particle-laden air through static-dissipative tubing to eliminate electrostatic losses in the tubing. Particles were generated using a medical nebulizer (MADA Up-Mist Medication Nebulizer) [51]. During the experiments, the RH was controlled by nebulizing deionized water using a separate nebulizer or introducing dry filtered air; tests were conducted in the range of RH = 17%– 80%. Two mixing fans inside the chamber provided well-mixed conditions through the experiments; particle concentration was continuously monitored.

thumbnail
Table 1. Characteristics of the standard testing aerosols used in the study [52].

https://doi.org/10.1371/journal.pone.0259745.t001

We controlled the aerosol generation rate by adjusting the compressed air flow rate to the nebulizer. The aerosol generation was stopped when the total number concentration (based on the APS count) reached 1000 #/cm3. Then, the particle concentration was allowed to decay as the chamber was evacuated at a rate of 9.8 L/min; the make-up air entering the test was aspirated through a HEPA filter. The sensor array data and the APS data were acquired via two universal serial buses (USB) cables in real-time until the total number concentration from the APS reached 15 #/cm3.

Data analysis and modeling

The collected data with concentrations > 1000 #/ cm3 were removed. The number concentration reported by the APS was aggregated as summarized in Table 2 to match the cumulative number concentrations of the PMS. The 1-second PMS measurement and 5-second APS measurement were aggregated to obtain 1-minute averaged data for calibration. The smallest size bin of the APS (< 0.523 μm) was used as a reference for calibrating PMS size bin > 0.3 μm.

thumbnail
Table 2. The PMS manufacturer’s specified size bins and mass indices with the corresponding reference APS aerodynamic size bins for calibration.

https://doi.org/10.1371/journal.pone.0259745.t002

Fig 3 shows the data from all six PMS sensors during the typical experimental run. In all experiments, the time-series of the uncalibrated concentration measurements from the six PMS sensors were consistent for all size bins (Pearson correlation coefficient (r) > 0.98) (S4S12 Figs). The data consistency between the six sensors allows us to develop generalized models by fusing the readings from all sensors and then correlating the data against the APS measurement with matching time stamps for each size bin. The calibrations models of the following form were fit for number concentration data from the APS and PMS:

thumbnail
Fig 3. Time-series plots of the uncalibrated, 1-second number concentration measurement from the six PMS sensors are presented.

The experiments were conducted under 30% relative humidity with W210 aerosols.

https://doi.org/10.1371/journal.pone.0259745.g003

(1) where APSt is the number concentration for each aggregated APS size bin at timestamp t; PMSt is the linear term of the PMS measurement (the number concentration of each PMS size bin) at timestamp t; RHt is the RH measurement of the Bosch BME680 sensor at timestamp t; β0 and β1 are regression coefficients; εt is the residual. In addition to Eq (1), other forms of linear models adjusted for relative humidity, particle density, and CRI were evaluated (S1 Table). For calibration of mass concentration, models including quadratic terms of the PMS measurement were evaluated (S1 Table). Since the test temperature variations were within ±2°C, the temperature was not included as a variable in the models. Based on a priori assumption that the PMS particle count and mass indices should be zero when the APS count is zero, the intercept (β0) of the models was set to zero. The number of terms included in the optimal calibration model for each size bin was determined based on the Bayesian Information Criterion (BIC). The models with lower BIC were chosen as the optimal models. After identifying the optimal models using BIC and estimating model coefficients, the model was then applied to the pre-calibrated 1-minute PMS measurement to produce the post-calibrated concentrations for model evaluation. Calibration performance was assessed using the normalized mean absolute error (NMAE), which was calculated using the following equation [53]: (2) where CPMS_post-cal is the post-calibrated 1-minute averaged PMS concentration and CAPS is the 1-minute averaged APS concentration. The linear models were fitted using the lm function in R. All the analyses were conducted using R version 3.6.3.

Results and discussion

Test conditions

During the experiments, the average temperature in the chamber was 24.8°C (range: 23.2 to 26.6°C), the RH was varied in the range of 17.5–79.4%, all experiments were performed at atmospheric pressure conditions. The one-minute APS total number concentration averaged 237.9 #/cm3 (range: 8.5 to 985.9 #/cm3). The one-minute PM2.5 measurement from the APS and PMS before calibration (6 sensors pooled together) averaged 106.0 μg/m3 (range: 1.9 to 641.3 μg/m3) and 51.5 μg/m3 (range: 0 to 218.8 μg/m3), respectively.

Particle size distribution

The particle size distribution of each test aerosol by the APS is shown in S3 Fig. The NaCl particles (from the nebulized liquid solution) were the smallest among the test aerosols, with nearly all particles < 3 μm. The W410 mixture had slightly larger particles than W210 and had the same CRI as W210 [52]. Fig 4 shows the typical particle size distributions reported by the PMS and the APS; the APS bins were aggregated to match the PMS. For all aerosols and all tested concentrations, the PMS appeared to underestimate particle counts for the size bin 0.5–1 μm and 1–2.5 μm. For larger size bins (2.5–5 μm and 5–10 μm), the PMS overestimate the particle counts. The particle count varies significantly in the lowest size bin (PMS: dp = 0.3–0.5 μm; APS: dp <0.523 μm). Both the APS and PMS use the optical channel. Since APS is a single particle instrument, its detection limit is based on the excitation wavelength, photodetector sensitivity, and particle optical properties; it is reported to be 0.37 μm. The PMS does not count every single particle; it relies on the internal calibration of the bulk scattering signal. The PMS OEM calibration significantly overestimates the counts in the 0.3–0.5 μm size range. For PMS, we measured the lower detection limit for the number concentration for the NaCl particles. In NaCl particle experiments, the initial (non-zero) response in the most sensitive PMS bin (dp > 0.3 μm) was observed at ~ 83 #/0.1 L as measured by APS. The PMS sensors seemed to follow the overall trends in the size distribution of the particles greater than 0.5 μm; however, the number concentration and particle sizing do not agree with the single-particle counter. Thus, calibration is needed if PMS is to be used for PM number concentration measurement.

thumbnail
Fig 4. A comparison of the size distribution measured by the APS and PMS using OEM calibration: Data from one of the six PMS for ATD, NaCl, W210, and W410 particles taken 15 minutes after the aerosols were introduced into the chamber.

The data from APS bins are aggregated to match the size bins reported by PMS. For PMS bin 0.3–0.5 μm, APS bin < 0.523 μm was used for comparison.

https://doi.org/10.1371/journal.pone.0259745.g004

Model fit

Despite the apparent shift in size distribution shown by Fig 4, a matrix of Pearson correlations between the PMS number concentrations (before calibration) and the APS reference number concentrations for different size ranges suggests that the matching size bins between the two instruments are well-correlated (S1 Fig). Notably, the PMS number concentration data correlated well with the APS for size bin up to 2.5 μm (r > 0.97). For measurement of size bin larger than 2.5 μm, the PMS exhibited moderate correlation with the APS (r <0.78). The worst correlation was observed for particles > 5 μm.

A similar Pearson correlation matrix comparing the mass concentrations measured by the PMS (before calibration) and the APS for different particle size ranges suggests a good correlation between matching sizes (S2 Fig). The PM1, PM2.5, and PM10 measurements by the PMS all exhibited high correlations with their corresponding sizes measured by the APS (r >0.90).

Because of the close correlations between corresponding APS and PMS size-specific measurements (S1 and S2 Figs), the sizes listed in Table 2 were chosen to develop calibration models for both PM number concentration and PM mass concentration. For example, APS size bin > 0.5 μm number concentrations was chosen as the reference (independent variable) for calibrating the PMS size bin > 0.5 μm number concentrations (dependent variable). Based on the same rationale, the corresponding APS mass concentration measurement was chosen as the reference for calibrating the PMS mass concentration index. The densities for each testing aerosol are shown in Table 1; these were used to determine the APS mass concentration measurement for calibration.

After fitting a set of alternative calibration model forms to the APS and PMS number concentration data, the results show excellent R2 and low NMAE for >0.3 μm, >0.5 μm, and >1 μm size bins when the full range of concentrations from 0–1000 #/cm3 was used for fitting (Table 3 and S2 Table). However, the model performance was worse for larger size bins, i.e., >2.5 μm, >5 μm, and >10 μm size bins. Based on the previous findings on the impacts of relative humidity on optical particle sensor output and particle optical properties, the models adjusted for CRI and RH were considered in addition to the linear model, see Table 3. For most size ranges, the relatively simple linear model without the CRI dependent term performed nearly as well as the models with the additional parameters. The BIC suggests that the models (shown in bold in S2 Table) with the adjustment for CRI and RH have similar NMAE. The table also includes the models based on the lower concentration data (data points with APS total number concentration <100 #/cm3). The models based on the low PM concentration do not perform as well as the full range concentration models.

thumbnail
Table 3. Summary of the calibration models for number concentration, R2, BIC, and the NMAE of the calibration models.

https://doi.org/10.1371/journal.pone.0259745.t003

The OEM calibration for PM mass concentration showed significantly better agreement with the reference instrument than the OEM number density calibration. An additional quadratic term was included for fitting mass concentration data, as shown in Table 4 and S3 Table. Similar to the number concentration models, restricting the mass concentration model to only lower concentrations (data points with APS total number concentration <100 #/cm3) resulted in worse performance vs. model based on the entire concentration range. The optimal models (shown in bold in S3 Table) included quadratic terms of PMS measurement, terms related to particle properties, and environmental conditions (CRI, density, and in some cases, RH) resulted in NMAE < 3.4% for the entire concentration range. Compared to the relatively simple linear models without these added parameters (CRI, density, and RH terms), the improvements in NMAE for models adjusted for these parameters tended to be larger than those observed for the number concentration models. The inclusion of quadratic term of PMS measurement in these optimal models also highlighted the non-linearity in the OEM’s mass concentrations estimates (Table 4 and S3 Table). CRI adjustment did not produce a significantly better fit for mass concentration calibration. In addition, the R2 values of the PM10 models (ranged between 0.85–0.88) are lower than the R2 values of the PM2.5 models (ranged between 0.94–0.96), which potentially indicated that the sensor performance dropped for particle size within the range of 2.5–10 μm. The poorer performance of the PMS for the coarse PM fraction was observed; the relationship between the estimated PMS and APS mass concentration values for the coarse size fraction (i.e., particle sizes from 2.5 to 10 μm) was markedly worse than smaller size fractions (S13 Fig).

thumbnail
Table 4. Summary of the calibration models for mass concentration a, R2, BIC, and the NMAE of the calibration models.

https://doi.org/10.1371/journal.pone.0259745.t004

Fig 5 shows a comparison between the pre-calibrated and post-calibrated PMS and APS particle number concentrations for full and lower concentration ranges. The pre-calibrated (OEM) number concentration vs. APS exhibits a linear trend over the entire range for all aerosols; however, the PMS underestimates the number of particles. The calibration significantly improves the agreement demonstrating the importance of calibration and the accuracy gains from applying calibrations. The simple linear relationship shows excellent agreement over the entire range of particle concentration and properties, the fitting parameter are shown in Table 3.

thumbnail
Fig 5. A comparison of the pre-calibrated and post-calibrated number concentrations by full and lower concentration range.

The blue line represents the 1:1 relationship between the PMS and APS concentration.

https://doi.org/10.1371/journal.pone.0259745.g005

For mass concentration (Fig 6), the PMS does not increase linearly compared to APS estimates, especially at higher concentrations. We do not have a satisfactory explanation for the non-linear trend when using the OEM calibration. Also, we observed a notable discrepancy in the PMS and APS relationship between ATD and other test aerosols, which may be related to a wide range of particle CRI in ATD; see Table 1. The graphical comparison is consistent with our results from Table 4 that shows lower NMAE for the models with a quadratic term. Overall, the mass concentration models adjusted for particle and environmental specific properties such as CRI, density, RH, as well as adjustment for non-linearity, seem to be necessary.

thumbnail
Fig 6. A comparison of the pre-calibrated and post-calibrated mass concentrations by full and lower concentration range.

The blue line represents the 1:1 relationship between the PMS and APS concentration.

https://doi.org/10.1371/journal.pone.0259745.g006

Conclusions

This study evaluated the PMS sensors and reported the calibration algorithm for both number concentration and mass concentration. We found that the PMS’s number concentrations can be corrected using a simple linear model, and mass concentrations can be better corrected using a polynomial model. Although the BIC indicated models adjusted for particle properties and environmental conditions are statistically superior, those models did not significantly improve NMAE. When restricting the fit to the lower concentration, the model’s accuracy decreases for both number and mass concentration, and the larger size bins tended to have higher errors. We used particles in a relatively narrow range of CRIs (1.53–1.64) and densities (1.03–2.7 g/cm3), and our RH was restricted within 17–80%. If the particle properties and environmental conditions of interest are significantly different from tested scenarios, one may need to consider these effects. Despite these limitations, these results are relevant when size-resolved number concentration is desired, especially for using these sensors in high concentration environments, including indoor air quality monitoring, occupational/industrial exposure assessments, or near-source monitoring scenarios. Since the test aerosols used in this study are applicable for several occupational health scenarios, a better exposure assessment could be achieved. In monitoring near-source and indoor air quality, where field calibration might be challenging, the more general algorithms applicable for a broader concentration range and known particle properties could substitute for the labor-intensive gravimetric measurements. The low-cost monitors also enable the development of distributed sensor networks with a much higher special resolution than those currently available from government air quality monitoring sites.

Supporting information

S1 Fig. Pearson correlation between the uncalibrated PMS number concentration (6 sensors pooled together) and APS number concentration for different size ranges.

https://doi.org/10.1371/journal.pone.0259745.s001

(TIF)

S2 Fig. Pearson correlation between the uncalibrated PMS mass concentration (6 sensors pooled together) and APS mass concentration for different size ranges.

https://doi.org/10.1371/journal.pone.0259745.s002

(TIF)

S3 Fig. The normalized particle size distribution of the Arizona Test Dust (ATD), NaCl, W210, and W410 measured by the APS.

The median diameter of the ATD, saline, W210 and W410 aerosol are 0.94 μm, 0.86 μm, 0.92 μm and 0.96 μm, respectively.

https://doi.org/10.1371/journal.pone.0259745.s003

(TIF)

S4 Fig. Pearson correlation between pairs of PMS for number concentration (for size range > 0.3 μm).

https://doi.org/10.1371/journal.pone.0259745.s004

(TIF)

S5 Fig. Pearson correlation between pairs of PMS for number concentration (for size range > 0.5 μm).

https://doi.org/10.1371/journal.pone.0259745.s005

(TIF)

S6 Fig. Pearson correlation between pairs of PMS for number concentration (for size range > 1 μm).

https://doi.org/10.1371/journal.pone.0259745.s006

(TIF)

S7 Fig. Pearson correlation between pairs of PMS for number concentration (for size range > 2.5 μm).

https://doi.org/10.1371/journal.pone.0259745.s007

(TIF)

S8 Fig. Pearson correlation between pairs of PMS for number concentration (for size range > 5 μm).

https://doi.org/10.1371/journal.pone.0259745.s008

(TIF)

S9 Fig. Pearson correlation between pairs of PMS for number concentration (for size range > 10 μm).

https://doi.org/10.1371/journal.pone.0259745.s009

(TIF)

S10 Fig. Pearson correlation between pairs of PMS for mass concentration (for PM1).

https://doi.org/10.1371/journal.pone.0259745.s010

(TIF)

S11 Fig. Pearson correlation between pairs of PMS for mass concentration (for PM2.5).

https://doi.org/10.1371/journal.pone.0259745.s011

(TIF)

S12 Fig. Pearson correlation between pairs of PMS for mass concentration (for PM10).

https://doi.org/10.1371/journal.pone.0259745.s012

(TIF)

S13 Fig. A comparison of the pre-calibrated PM1, PM2.5, PM10, and PMcoarse size fraction (i.e., particle sizes from 2.5 to 10 μm).

https://doi.org/10.1371/journal.pone.0259745.s013

(TIF)

S14 Fig. A comparison of the pre-calibrated and post-calibrated number concentrations by different size bins.

https://doi.org/10.1371/journal.pone.0259745.s014

(TIF)

S1 Table. Forms of linear model fitted for number concentration and mass concentration for calibration.

https://doi.org/10.1371/journal.pone.0259745.s015

(DOCX)

S2 Table. Summary of the R2, Bayesian Information Criterion (BIC), and the Normalized Mean Absolute Error (NMAE) of the calibration models for number concentration.

https://doi.org/10.1371/journal.pone.0259745.s016

(DOCX)

S3 Table. Summary of the R2, Bayesian Information Criterion (BIC), and the Normalized Mean Absolute Error (NMAE) of the calibration models for mass concentration.

https://doi.org/10.1371/journal.pone.0259745.s017

(DOCX)

Acknowledgments

The authors wish to express special thanks to William Lin and Koustubh Muluk, the students at the University of Washington, for helping to run the aerosol chamber tests in this study.

References

  1. 1. Beelen R, Hoek G, van den Brandt PA, Goldbohm RA, Fischer P, Schouten LJ, et al. Long-Term Effects of Traffic-Related Air Pollution on Mortality in a Dutch Cohort (NLCS-AIR Study). Environmental Health Perspectives. 2008;116(2):196–202. PMC2235230. pmid:18288318
  2. 2. Krewski D, Burnett RT, Goldberg MS, Hoover BK, Siemiatycki J, Jerrett M, et al. Overview of the reanalysis of the Harvard Six Cities Study and American Cancer Society Study of Particulate Air Pollution and Mortality. J Toxicol Environ Health A. 2003;66(16–19):1507–51. Epub 2003/09/10. pmid:12959828.
  3. 3. Krewski D, Jerrett M, Burnett RT, Ma R, Hughes E, Shi Y, et al. Extended follow-up and spatial analysis of the American Cancer Society study linking particulate air pollution and mortality. Research report (Health Effects Institute). 2009;(140):5–114; discussion 5–36. Epub 2009/07/25. pmid:19627030.
  4. 4. Pope CA 3rd, Burnett RT, Thun MJ, Calle EE, Krewski D, Ito K, et al. Lung cancer, cardiopulmonary mortality, and long-term exposure to fine particulate air pollution. Jama. 2002;287(9):1132–41. Epub 2002/03/07. pmid:11879110; PubMed Central PMCID: PMC4037163.
  5. 5. Pope CA 3rd, Dockery DW. Health effects of fine particulate air pollution: lines that connect. J Air Waste Manag Assoc. 2006;56(6):709–42. Epub 2006/06/30. pmid:16805397.
  6. 6. Pope CA 3rd, Thun MJ, Namboodiri MM, Dockery DW, Evans JS, Speizer FE, et al. Particulate air pollution as a predictor of mortality in a prospective study of U.S. adults. Am J Respir Crit Care Med. 1995;151(3 Pt 1):669–74. Epub 1995/03/01. pmid:7881654.
  7. 7. Samet JM, Dominici F, Curriero FC, Coursac I, Zeger SL. Fine particulate air pollution and mortality in 20 U.S. cities, 1987–1994. The New England journal of medicine. 2000;343(24):1742–9. Epub 2000/12/15. pmid:11114312.
  8. 8. Cohen AJ, Anderson HR, Ostro B, Pandey KD, Krzyzanowski M, Künzli N, et al. Urban air pollution. Comparative quantification of health risks: global and regional burden of disease attributable to selected major risk factors. 2004;2:1353–433.
  9. 9. Brown JS, Zeman KL, Bennett WD. Ultrafine particle deposition and clearance in the healthy and obstructed lung. Am J Respir Crit Care Med. 2002;166(9):1240–7. Epub 2002/10/31. pmid:12403694.
  10. 10. Schwartz J, Neas LM. Fine Particles Are More Strongly Associated Than Coarse Particles with Acute Respiratory Health Effects in Schoolchildren. Epidemiology. 2000;11(1):6–10. pmid:10615836
  11. 11. Elbayoumi M, Ramli NA, Md Yusof NFF. Spatial and temporal variations in particulate matter concentrations in twelve schools environment in urban and overpopulated camps landscape. Building and Environment. 2015;90:157–67. http://dx.doi.org/10.1016/j.buildenv.2015.03.036.
  12. 12. Patel MM, Chillrud SN, Correa JC, Feinberg M, Hazi Y, Kc D, et al. Spatial and Temporal Variations in Traffic-related Particulate Matter at New York City High Schools. Atmospheric environment (Oxford, England: 1994). 2009;43(32):4975–81. PMC2791330. pmid:20161461
  13. 13. Directive 2008/50/EC of the European Parliament and of the Council of 21 May 2008 on ambient air quality and cleaner air for Europe, (2008).
  14. 14. EPA. 40 CFR Parts 50—Reference Methods for the Determination of Fine Particulate Matter as PM2.5 in the Atmosphere (Appendix L). In: EPA, editor. 1997a.
  15. 15. Seto E, Austin E, Novosselov I, Yost MG, editors. Use of low-cost particle monitors to calibrate traffic-related air pollutant models in urban areas. International Environmental Modelling and Software Society; 2014.
  16. 16. Liu X, Jayaratne R, Thai P, Kuhn T, Zing I, Christensen B, et al. Low-cost sensors as an alternative for long-term air quality monitoring. Environmental research. 2020;185:109438. pmid:32276167
  17. 17. Kuhn T, Jayaratne R, Thai PK, Christensen B, Liu X, Dunbabin M, et al. Air quality during and after the Commonwealth Games 2018 in Australia: Multiple benefits of monitoring. Journal of Aerosol Science. 2021;152:105707.
  18. 18. Jiao W, Hagler G, Williams R, Sharpe R, Brown R, Garver D, et al. Community Air Sensor Network (CAIRSENSE) project: evaluation of low-cost sensor performance in a suburban environment in the southeastern United States. Atmospheric Measurement Techniques. 2016;9(11):5281–92. pmid:32802212
  19. 19. Makhsous S, Segovia JM, He J, Chan D, Lee L, Novosselov IV, et al. Methodology for Addressing Infectious Aerosol Persistence in Real-Time Using Sensor Network. Sensors. 2021;21(11):3928. pmid:34200380
  20. 20. Hegde S, Min KT, Moore J, Lundrigan P, Patwari N, Collingwood S, et al. Indoor household particulate matter measurements using a network of low-cost sensors. Aerosol and Air Quality Research. 2020;20(2):381–94.
  21. 21. Li J, Li H, Ma Y, Wang Y, Abokifa AA, Lu C, et al. Spatiotemporal distribution of indoor particulate matter concentration with a low-cost sensor network. Building and Environment. 2018;127:138–47.
  22. 22. Duncan GE, Seto E, Avery AR, Oie M, Carvlin G, Austin E, et al. Usability of a personal air pollution monitor: Design-feedback iterative cycle study. JMIR mHealth and uHealth. 2018;6(12):e12023. pmid:30578204
  23. 23. Cordero JM, Borge R, Narros A. Using statistical methods to carry out in field calibrations of low cost air quality sensors. Sensors and Actuators B: Chemical. 2018;267:245–54. https://doi.org/10.1016/j.snb.2018.04.021.
  24. 24. Feenstra B, Papapostolou V, Hasheminassab S, Zhang H, Boghossian BD, Cocker D, et al. Performance evaluation of twelve low-cost PM2.5 sensors at an ambient air monitoring site. Atmospheric Environment. 2019;216:116946. https://doi.org/10.1016/j.atmosenv.2019.116946.
  25. 25. Kelly KE, Whitaker J, Petty A, Widmer C, Dybwad A, Sleeth D, et al. Ambient and laboratory evaluation of a low-cost particulate matter sensor. Environmental Pollution. 2017;221:491–500. pmid:28012666
  26. 26. Sayahi T, Butterfield A, Kelly KE. Long-term field evaluation of the Plantower PMS low-cost particulate matter sensors. Environmental Pollution. 2019;245:932–40. pmid:30682749
  27. 27. Tryner J, L’Orange C, Mehaffy J, Miller-Lionberg D, Hofstetter JC, Wilson A, et al. Laboratory evaluation of low-cost PurpleAir PM monitors and in-field correction using co-located portable filter samplers. Atmospheric Environment. 2020;220:117067. https://doi.org/10.1016/j.atmosenv.2019.117067.
  28. 28. Wang Z, Delp WW, Singer BC. Performance of low-cost indoor air quality monitors for PM2.5 and PM10 from residential sources. Building and Environment. 2020;171:106654. https://doi.org/10.1016/j.buildenv.2020.106654.
  29. 29. Zusman M, Schumacher CS, Gassett AJ, Spalt EW, Austin E, Larson TV, et al. Calibration of low-cost particulate matter sensors: Model development for a multi-city epidemiological study. Environ Int. 2020;134:105329. pmid:31783241
  30. 30. Austin E, Novosselov I, Seto E, Yost MG. Laboratory Evaluation of the Shinyei PPD42NS Low-Cost Particulate Matter Sensor. PloS one. 2015;10(9):e0137789. pmid:26367264
  31. 31. Phuleria HC, Fine PM, Zhu Y, Sioutas C. Air quality impacts of the October 2003 Southern California wildfires. Journal of Geophysical Research: Atmospheres. 2005;110(D7).
  32. 32. Wallace LA, Emmerich SJ, Howard-Reed C. Source Strengths of Ultrafine and Fine Particles Due to Cooking with a Gas Stove. Environ Sci Technol. 2004;38:2304–11. pmid:15116834
  33. 33. Afshar-Mohajer N, Wu C-Y, Ladun T, Rajon DA, Huang Y. Characterization of particulate matters and total VOC emissions from a binder jetting 3D printer. Building and Environment. 2015;93:293–301. https://doi.org/10.1016/j.buildenv.2015.07.013.
  34. 34. Kinney PL, Gichuru MG, Volavka-Close N, Ngo N, Ndiba PK, Law A, et al. Traffic Impacts on PM(2.5) Air Quality in Nairobi, Kenya. Environ Sci Policy. 2011;14(4):369–78. pmid:21779151.
  35. 35. Chen J, Li C, Ristovski Z, Milic A, Gu Y, Islam MS, et al. A review of biomass burning: Emissions and impacts on air quality, health and climate in China. Science of The Total Environment. 2017;579:1000–34. pmid:27908624
  36. 36. Gall ET, Carter EM, Earnest CM, Stephens B. Indoor air pollution in developing countries: research and implementation needs for improvements in global public health. Am J Public Health. 2013;103(4):e67–e72. Epub 2013/02/14. pmid:23409891.
  37. 37. Sousan S, Koehler K, Thomas G, Park JH, Hillman M, Halterman A, et al. Inter-comparison of low-cost sensors for measuring the mass concentration of occupational aerosols. Aerosol Science and Technology. 2016;50(5):462–73. pmid:28867868
  38. 38. Wang Y, Li J, Jing H, Zhang Q, Jiang J, Biswas P. Laboratory Evaluation and Calibration of Three Low-Cost Particle Sensors for Particulate Matter Measurement. Aerosol Science and Technology. 2015;49(11):1063–77.
  39. 39. Renard JB, Dulac F, Berthet G, Lurton T, Vignelles D, Jégou F, et al. LOAC: a small aerosol optical counter/sizer for ground-based and balloon measurements of the size distribution and nature of atmospheric particles–Part 1: Principle of measurements and instrument evaluation. Atmos Meas Tech. 2016;9(4):1721–42.
  40. 40. Nagy A, Szymanski WW, Gál P, Golczewski A, Czitrovszky A. Numerical and experimental study of the performance of the dual wavelength optical particle spectrometer (DWOPS). Journal of Aerosol Science. 2007;38(4):467–78. http://dx.doi.org/10.1016/j.jaerosci.2007.02.005.
  41. 41. Njalsson T, Novosselov I. Design and Optimization of a Compact Low-cost Optical Particle Sizer. Journal of Aerosol Science. 2018. pmid:30270936
  42. 42. Molenar JV, editor Theoretical Analysis of PM 2. 5 Mass Measurements by Nephelometry-# 1102003.
  43. 43. Liu H-Y, Schneider P, Haugen R, Vogt M. Performance Assessment of a Low-Cost PM2.5 Sensor for a near Four-Month Period in Oslo, Norway. Atmosphere. 2019;10:41.
  44. 44. Jayaratne R, Liu X, Thai P, Dunbabin M, Morawska L. The influence of humidity on the performance of a low-cost air particle mass sensor and the effect of atmospheric fog. Atmos Meas Tech. 2018;11(8):4883–90.
  45. 45. Chakrabarti B, Fine PM, Delfino R, Sioutas C. Performance evaluation of the active-flow personal DataRAM PM2.5 mass monitor (Thermo Anderson pDR-1200) designed for continuous personal exposure measurements. Atmospheric Environment. 2004;38(20):3329–40. https://doi.org/10.1016/j.atmosenv.2004.03.007.
  46. 46. Sioutas C, Kim S, Chang M, Terrell LL, Gong H. Field evaluation of a modified DataRAM MIE scattering monitor for real-time PM2.5 mass concentration measurements. Atmospheric Environment. 2000;34(28):4829–38. https://doi.org/10.1016/S1352-2310(00)00244-2.
  47. 47. Malm WC, Day DE, Kreidenweis SM. Light scattering characteristics of aerosols as a function of relative humidity: Part I—A comparison of measured scattering and aerosol concentrations using the theoretical models. Journal of the Air & Waste Management Association. 2000;50(5):686–700. WOS:000086986300005. pmid:28080837
  48. 48. Manikonda A, Zíková N, Hopke PK, Ferro AR. Laboratory assessment of low-cost PM monitors. Journal of Aerosol Science. 2016;102:29–40. https://doi.org/10.1016/j.jaerosci.2016.08.010.
  49. 49. Vaddi RS, Guan Y, Novosselov I. Behavior of ultrafine particles in electro-hydrodynamic flow induced by corona discharge. Journal of Aerosol Science. 2020:105587. pmid:32704186
  50. 50. He JY, Novosselov IV. Design and evaluation of an aerodynamic focusing micro-well aerosol collector. Aerosol Science and Technology. 2017;51(9):1016–26. WOS:000416683600002. pmid:30739977
  51. 51. Vaddi RS, Guan Y, Novosselov I. Particle Dynamics in Corona Induced Electro-hydrodynamic Flow. arXiv:190202986. 2019.
  52. 52. Shefelbine T, Forehand C, Rink K. 3MTM Ceramic Microspheres in Architectural Paint. 2015.
  53. 53. Xiang J, Austin E, Gould T, Larson T, Yost M, Shirai J, et al. Using Vehicles’ Rendezvous for In Situ Calibration of Instruments in Fleet Vehicle-Based Air Pollution Mobile Monitoring. Environmental Science & Technology. 2020;54(7):4286–94. pmid:32150678