Skip to main content
Advertisement
Browse Subject Areas
?

Click through the PLOS taxonomy to find articles in your field.

For more information about PLOS Subject Areas, click here.

  • Loading metrics

Improved Detection of Rare HIV-1 Variants using 454 Pyrosequencing

  • Brendan B. Larsen ,

    Contributed equally to this work with: Brendan B. Larsen, Lennie Chen

    Affiliation Department of Microbiology, University of Washington, Seattle, Washington, United States of America

  • Lennie Chen ,

    Contributed equally to this work with: Brendan B. Larsen, Lennie Chen

    Affiliation Department of Microbiology, University of Washington, Seattle, Washington, United States of America

  • Brandon S. Maust,

    Affiliation Department of Microbiology, University of Washington, Seattle, Washington, United States of America

  • Moon Kim,

    Affiliation Department of Microbiology, University of Washington, Seattle, Washington, United States of America

  • Hong Zhao,

    Affiliation Department of Microbiology, University of Washington, Seattle, Washington, United States of America

  • Wenjie Deng,

    Affiliation Department of Microbiology, University of Washington, Seattle, Washington, United States of America

  • Dylan Westfall,

    Affiliation Department of Microbiology, University of Washington, Seattle, Washington, United States of America

  • Ingrid Beck,

    Affiliations Children’s Hospital Research Institute, Seattle, Washington, United States of America, Department of Pediatrics, University of Washington, Seattle, Washington, United States of America

  • Lisa M. Frenkel,

    Affiliations Children’s Hospital Research Institute, Seattle, Washington, United States of America, Department of Pediatrics, University of Washington, Seattle, Washington, United States of America, Department of Laboratory Medicine, University of Washington, Seattle, Washington, United States of America

  • James I. Mullins

    jmullins@uw.edu

    Affiliations Department of Microbiology, University of Washington, Seattle, Washington, United States of America, Department of Pediatrics, University of Washington, Seattle, Washington, United States of America, Department of Medicine, University of Washington, Seattle, Washington, United States of America

Abstract

454 pyrosequencing, a massively parallel sequencing (MPS) technology, is often used to study HIV genetic variation. However, the substantial mismatch error rate of the PCR required to prepare HIV-containing samples for pyrosequencing has limited the detection of rare variants within viral populations to those present above ~1%. To improve detection of rare variants, we varied PCR enzymes and conditions to identify those that combined high sensitivity with a low error rate. Substitution errors were found to vary up to 3-fold between the different enzymes tested. The sensitivity of each enzyme, which impacts the number of templates amplified for pyrosequencing, was shown to vary, although not consistently across genes and different samples. We also describe an amplicon-based method to improve the consistency of read coverage over stretches of the HIV-1 genome. Twenty-two primers were designed to amplify 11 overlapping amplicons in the HIV-1 clade B gag-pol and env gp120 coding regions to encompass 4.7 kb of the viral genome per sample at sensitivities as low as 0.01-0.2%.

Introduction

Pyrosequencing using the Roche/454 platform has been used to study HIV-1 transmission [1,2], emergence of drug resistance [3-5], and superinfection [6,7]. Pyrosequencing allows many relatively long DNA templates to be sequenced in parallel (~350nt with product literature promising >600bp), generating more than 1 million sequences in a single run. However, the promise of “deep” sequencing of variable sequence populations such as within HIV infections, using MPS on the 454 and other platforms, has been slow to materialize in part because of the complexities introduced by PCR. Nested PCR, often involving 70 or more rounds of amplification of the typically low abundance HIV target molecules, is often required to obtain sufficient numbers for detection and subsequent use in these instruments. Substitution errors that occur during these initial PCR steps will be observed following parallel sequencing of the target molecules, and, in most cases, cannot be reliably distinguished from true viral genetic variation.

Accurate detection and quantitation of low-frequency variants is dependent on four main factors: quantitation of amplifiable input template molecules, removal of artifactual errors that occur during the pyrosequencing reactions (homopolymer length variation and carry-forward errors), minimization of misincorporation error rates during preliminary PCR steps, and consistent and adequate read coverage of the sample population.

In the case of HIV infection, plasma viral loads are determined using clinical assays using standard controls to account for inefficiencies in the extraction and reverse transcription of nucleic acids and compounds in the specimen that inhibit amplification. Thus, reported values are often extrapolations of the actual number of genome fragments amplified [8,9]. Furthermore, the highly conserved regions amplified by commercial assays are seldom of interest in research studies. Following clinical viral load assay a sample might also experience multiple freeze-thaw cycles that will degrade virions and viral RNA. PCR efficiency is also highly dependent upon the specificity of the primers, the PCR conditions, and the length of the amplicon. Hence, in calculating the number of amplifiable templates, it is crucial to use the exact PCR conditions that will be employed for acquiring sequencing templates. Without careful estimation of the number of amplifiable input molecules, an incorrect representation of the population diversity will result [10-12].

Due to miscalled lengths of homopolymer runs, pyrosequencing results in a very large number of errors by creating artifactual insertions or deletions (InDels) in the sequence reads. Several algorithms have been put forth to remove most of these errors [13-17]. To allow real variants to be distinguished from errors that occurred prior to pyrosequencing, a frequency threshold above the error rate of PCR should be defined. Errors resulting from both PCR and pyrosequencing have been well described [18-20]. Misincorporation errors during pyrosequencing are typically not a problem, as thousands of templates are extended on individual beads during each flow cycle, and most will incorporate the correct base. The mean mismatch error rate of 454 without any PCR has been reported to be 0.02% which is significantly lower than the error-rate when PCR is used to amplify samples prior to 454 sequencing [19]. Therefore, the biggest source of mismatch error in 454 sequencing comes from the PCR used to initially amplify the samples.

Thus, pyrosequencing errors primarily result in miscalls of the length of homopolymers, while PCR amplification of templates prior to 454 is associated with substitution errors. Distinguishing background PCR misincorporation errors from real low-level variation represents a significant obstacle for the analysis of pyrosequencing data. Some publications have noted the problem of miscalling PCR and pyrosequencing errors as real variants [21,22], and a variety of computational methods have been developed that attempt to distinguish real variation from error [13-17]. Some of these computational methods rely on flowgram or quality score information to infer whether a variant is real. Since quality scores and flowgrams are limited to the probability of only errors that occur during pyrosequencing, they cannot be used to correct substitution errors that accumulate during the PCR stage before emPCR. Application of random bar codes on cDNA or PCR primers allows for determination of a consensus for each sequence, and thus will obviate much of the error that occurs during the initial PCR steps. However, this approach is only practical for short amplicons that include the 3’ end or both ends of the template [23,24].

Lastly, to detect low-frequency variants, there must be sufficient sequence coverage. The term “coverage” has sometimes been used to mean the number of reads obtained in the sequencing run. However, the number of reads cannot be taken to indicate the number of templates sequenced, unless there are fewer reads than the initial number of amplifiable templates in the PCR reaction and unless each read encompasses the full length of the amplicon being sequenced. Even when the number of reads is fewer than the number of templates, each read can only approximate the actual template sequence due to PCR and pyrosequencing errors. Our approach involves over-sequencing each template, and then using a frequency cutoff, derived from the number of templates, to estimate the detection limit of rare variants. Therefore, our usage of “coverage” indicates the degree of over-sequencing of each template, and is defined as the number of reads at a particular position divided by the number of templates.

Coverage by either definition varies by position in a template, because the DNA is often sheared to build libraries for pyrosequencing. Shearing techniques tend to produce uneven read coverage, in which one position might have thousands of reads, while another position a short distance away might have only a few reads. A comparison of three different library shearing methods found regions of uneven read coverage was an issue in all three [25].

The methods employed here included an attempt to overcome the problem of uneven coverage by creating a series of overlapping amplicons of approximately the length of pyrosequencing reads. We designed a total of twenty-two 2nd round primers to amplify 11 overlapping amplicons that span the gag-pol and env gp120 coding sequences of HIV-1. While such methods could be applied to any template population or any region of HIV-1, we focused on developing a method for sequencing these regions because of their use as immunogens (gag) and control regions (env) in a recent HIV vaccine clinical trial [26,27].

We report methods for increasing the sensitivity of detection of low-level variants in sequence populations through optimization of PCR conditions and choice of DNA polymerases. Through these improvements we have reduced the threshold of detection of low-level variants to 0.02-0.1%.

Methods

RNA extraction and cDNA synthesis

HIV-1 RNA was extracted from the plasma of infected individuals using the QIAamp Viral RNA Mini Kit (Qiagen, Valencia, CA) according to the manufacturer’s protocol. A total of 560µL plasma was extracted and eluted in 80µL elution buffer. cDNA was synthesized using 10 µl of RNA and the Takara BluePrint First Strand Synthesis Kit (Clontech 6115A) according to the manufacturer’s protocol. cDNA was synthesized with gene specific primers, R3337-1 (5’- TTTCCYACTAAYTTYTGTATRTCATTGAC-3’) for gag-pol and R9048 (5’-AGCTSCCTTGTAAGTCATTGGTCTTARA-3’) for gp120, at 400nM final concentration.

PCR and sequencing

First-round reactions used 2,000 copies of pNL4-3 [28], a plasmid containing a full-length HIV-1 genome, as the template, except in the case of the enzyme sensitivity comparison in which we used a patient plasma sample as a source of viral RNA. We also applied our methods to specimens from five additional subjects recruited through the University of Washington HIV Primary Infection Clinic [29]. The plasma viral loads for these 6 specimens are shown in Table S1. To sequence a 2.6 kb fragment of the HIV-1 gag -pol gene region and a 2.1 kb fragment of env, first- and second-round PCRs were performed using Kapa HiFi HS (Kapa Biosystems, Boston) (Table 1). In brief, first-round PCR reactions were conducted in two separate 25 µL reaction volumes with 1-6 µL of cDNA as template, corresponding to 200 to 500 input template copies based on limiting endpoint dilution PCR using the template estimator program Quality [10] (http://indra.mullins.microbiol.washington.edu/quality/). Second-round PCR reactions were conducted in 25 µl, using 2 µl of the first round reaction as template. A total of five multiplex PCR and one Monoplex PCR were performed to generate 11 overlapping PCR amplicons ranging from 384-603 bp in size. Primer sets and sequences are listed in Table 2. To accommodate the exceptional sequence diversity of HIV genomes, we utilized nucleotide frequencies across the HIV genome derived from the Los Álamos HIV database to design our primers to bind to conserved regions of the HIV genome. Second-round PCR reaction products were pooled and purified using AMPure beads according to the manufacturer’s protocol (Agencourt, Beverly, MA). Briefly, 180 µL of PCR product was mixed with 144 µL of AMPure beads. The solution was then vortexed, incubated, washed, and purified. Finally the beads were resuspended in 60 µL of 10mM Tris-Cl. A Nanodrop instrument (Thermo Scientific; Waltham, MA) was used to determine DNA concentration and purity. The purified product was then diluted to 100ng/µL with 10mM Tris-Cl. All purified products were stored at -20°C prior to sequencing.

1st Round PCR (25 µl reaction volumes)
EnzymeReaction compositionCycling conditions
Advantage21X Adv2 buffer, 200 µM dNTP, 400 nM primers, 1X Adv2 Pol Mix94°C 3 min. 35 cycles: 94°C 20 sec, 64°C 20 sec, 68°C 2 min. 1 cycle: 68°C 7 min. 4°C hold
Phusion1X Master Mix, 500 nM primers98°C 1 min. 35 cycles: 98°C 10 sec, 64°C 30 sec, 72°C 1 min. 1 cycle: 72°C 7 min. 4°C hold
KOD HSKOD 1X buffer, 1.5 mM MgSO4, 200 µM dNTP, 400 nM primers, 0.5U KOD HS DNA Polymerase95°C 2 min. 35 cycles: 95°C 20 sec, 64°C 20 sec, 70°C 1 min. 1 cycle: 70°C 7 min. 4°C hold
Kapa HiFi Hot Start1X Kapa HiFi Fidelity Buffer, 300 µM each dNTP, 500 nM primers, 0.5 U Kapa HiFi HS DNA Pol95°C 2 min. 35 cycles: 98°C 20 sec, 64°C 30 sec, 72°C 1.5 min. 1 cycle: 72°C 5 min. 4°C hold
2nd Round PCR (25 µl reaction volumes)
EnzymeReaction compositionCycling conditions
Advantage21X Advantage 2 PCR Buffer, 280 µM dNTP, 400 nM primers, 1X Advantage 2 Polymerase Mix, 2 µl 1st round PCR reaction94°C 3 min. 5 cycles: 94°C 15 sec, 60°C 25 sec, 68°C 10 sec. 25 cycles: 94°C 15 sec, 64°C 15 sec, 68°C 10 sec. 1 cycle: 68°C 7 min. 4°C hold
Kapa HiFi Hot Start1X Kapa HiFi Fidelity Buffer, 300 µM dNTP, 400 nM primers, 0.5 U Kapa HiFi HS DNA Polymerise, 2 µl 1st round PCR reaction95°C 2 min. 5 cycles: 98°C 20 sec, 58° 30 sec, 72°C 10 sec. 30 cycles: 98°C 20 sec, 64°C 30 sec, 72°C 10 sec. 1 cycle: 72°C 5 min. 4°C hold

Table 1. PCR conditions.

CSV
Download CSV
1st Round PCR
PrimerAmpliconSequenceAmplicon Size
F683gag-polCTCTCGACGCAGGACTCGGCTTG2654
R3337-1gag-polTTTCCYACTAAYTTYTGTATRTCATTGAC
F5957-1gp120TTAGGCATYTYCTATGGCAGGAAGAA2096
R8053-1gp120CAAGGCACAKYAGTGGTGCARATGA
2nd Round PCR
PrimerAmpliconPrimer SetSequenceAmplicon SizeAverage # forward readsAverage # reverse reads
F762gagp171TTGACTAGCGGAGGCTAGAAGGAGA50448614560
R1196gagp171TGCACTATAGGGTAATTTTGGCTGAC
F1099gagp24a2ATAGAGGAAGAGCAAAACAAAAGTAAGA60351735454
R1632gagp24a2GCTRGYAGGGCTATACATYCTTACTAT
F1550alt1gagp24b3CACCTATCCCAGTAGGAGAMATYTATA50579547874
R1985gagp24b3CCTTCYTTGCCACARTTGAAACAYTT
F2195pol14AACARCARCYCCCYCTCAGAARCAGG496899710222
R2621pol14CCAYTGTTTAACYTTTGGKCCATCCATT
F2548pol21TTCCCATTAGTCCTATTGAAACTGTAC56281017618
R3040pol21ATRCTRCWTTGGAATATTGCTGGTGAT
F2966pol35ACCAGGGATTAGATATCAGTACAATGT384111169515
R3280pol35ATAGGCTGTACTGTCCATTTATCAGG
F6191env15GATAGAMTAAKAGAAAGAGCAGAAGACA50278599016
R6623env15ATCMGTGCAAKTTAAAGTAACACAGAGT
F6547alt1env22TAATCAGTTTATGGGATSAAAGYYTAAA4951181412123
R6972env22CATGTGTACATTGTACTGTGCTGACAT
F6853alt1env34TTGARCCAATTCCYATACATTAYTGTR39188149441
R7174env34AATGCTCTYCCTGGTCCYATATGTAT
F7111alt1env46GTACAAGACCCAACAACAATACAAGRA5421205813109
R7583alt2env46TADTAGCCCTGTAATATTTGATRARCA
F7504alt1env53GGCARGARGTAGGAARAGCAATRTATG59777038605
R8031env53TGAGYTTTCCAGAGCARCCCCAAAT

Table 2. List of primers used to amplify viral DNA prior to pyrosequencing.

CSV
Download CSV

Comparison of DNA polymerases

To compare the error rate and sensitivity of the PCR enzymes, four different DNA polymerases were used to amplify two amplicons (named gagp24b, 505bp, and env5, 597bp) within the HIV-1 genome. The enzymes used were Advantage 2 (Adv2; Clontech, Mountain View, CA), Phusion High Fidelity DNA polymerase (New England Biolabs, Ipswich, MA), KOD Hot Start DNA polymerase (EMD Millipore, Billerica, MA) and Kapa HiFi Hot Start (Kapa Biosystems; Boston, MA). First-round PCR reactions were conducted in two separate 25 µL reactions with primers (gag-pol: F683 5’- CTCTCGACGCAGGACTCGGCTTG-3’ and R3337-1 5’- TTTCCYACTAAYTTYTGTATRTCATTGAC-3’) and (env gp120: F5957-1 5’- TTAGGCATYTYCTATGGCAGGAAGAA-3’ and R8053-1 5’- CAAGGCACAKYAGTGGTGCARATGA-3’). Equal volumes of each first-round PCR were then combined, and 2 µL was used as template in 25 µL total reaction volumes in a second-round nested PCR. Multiplex second-round PCRs used one pair of primers (Primer set 3, Table 2), which targeted genes of interest within the first-round PCR amplicons. The second-round primers also contained universal adaptors A and B, as well as one of seven different MIDs described by Roche: ACGAGTGCGT, ACGCTCGACA, AGACGCACTC, AGCACTGTAG, ATCAGACACG, ATATCGCGAG, and CGTGTCTCTA (Roche, Basel, Switzerland). PCR conditions and cycling parameters for each DNA polymerase are listed in Table 1.

Second-round PCR products were visualized on a QIAxcel (Qiagen, Hilden, Germany). Confirmed positive reactions were pooled and purified using AMPure beads as outlined above.

454: Pyrosequencing

Briefly, each pooled and purified PCR product was quantified using the Quan-it PicoGreen dsDNA assay (Invitrogen, Carlsbad, CA). Each product was then diluted to a working stock of 107 molecules/µl in TE buffer. All 11 amplicons were then pooled together in equimolar ratios into a single tube for pyrosequencing.

Emulsion PCR and sequencing were performed according to the manufacturer’s GS FLX Titanium protocols (Roche, Basel, Switzerland). PCR products were added to the emulsion PCR at a ratio of 1-2 molecules per bead. The picotiter sequencing plate was prepared with a single gasket, creating two regions. Four million enriched beads were loaded equally across the two regions. All error rate comparison data were derived from the same sequencing plate, while the patient samples were run on separate plates.

Error Rate Calculations

First, raw sequences were screened to remove any reads that were less than 100 bp or contained the ambiguous base ‘N’. Sequences generated for each sample were then aligned to the pNL4-3 reference or a patient specific consensus using BLAST [30] with the following parameters: match: 1; mismatch: -1; gap existence: 1; gap extension: 2. We performed pairwise alignment by applying the NCBI BLASTN program to measure different types of errors (insertions, deletions and substitutions). Second, a perl script was used to parse the BLAST pairwise alignment output XML file (parseBlastXML_calcErrRate.pl, available at http://indra.mullins.microbiol.washington.edu/). For each pairwise alignment between read and the reference, the script counts the number of aligned nucleotides in the reference sequence, as well as the numbers of insertions, deletions and substitutions in the read compared to the reference. By processing all the reads that aligned to the reference, the total numbers of aligned nucleotides in the reference sequence and different types of errors were calculated. All site specific errors were then tabulated and the mean frequencies and 95% confidence intervals were calculated

Statistical Analyses

The program Quality [10] was used to calculate the number of amplifiable templates in each sample with data generated from nested PCR following endpoint dilution (positive or negative amplifications monitored by gel electrophoresis). Quality is a web tool (http://indra.mullins.microbiol.washington.edu/quality/) based on the minimum chi method developed by Taswell [31] for limiting dilution assays.

The difference in error rates between enzymes was compared using a Kruskal-Wallis ANOVA test with Dunn’s multiple comparison correction to compare multiple enzymes simultaneously. P-values < 0.05 were considered significant. All statistical tests were conducted using GraphPad Prism 6.0 for Mac (GraphPad, San Diego).

Results

Sensitivity of PCR as a function of the Polymerases Used

We first compared the sensitivity of 6 different enzyme combinations by limiting dilution endpoint PCR for PIC subject 64236 (RNA) and the plasmid clone pNL4-3 (DNA) (Table 3). The sensitivity of different enzymes did vary, but not consistently across different genes or samples. A seventh combination that employed the use of Phusion in both rounds of PCR resulted in consistently low sensitivity, and was not tested further (data not shown).

EnzymeSamplePol Mean c/µL (SD*)Env Mean c/µL (SD*)
Adv2/Adv264236 Plasma2.0 + 0.57.5 + 2.4
Phusion/Adv264236 Plasma8.3 + 3.44.7 + 1.5
Phusion/Adv2 (25 cycles)64236 Plasma8.3 + 3.44.7 + 1.5
KOD/Adv264236 Plasma2.1 + 0.56.0 + 2.1
Phusion/Kapa HiFi64236 Plasma8.3 + 3.44.7 + 1.5
Kapa HiFi/Kapa HiFi64236 Plasma6.1 + 2.14.5 + 1.7
Adv2/Adv2pNL4-3228 + 14291 + 57
Phusion/Adv2pNL4-3228 + 142228 + 142
Phusion/Adv2 (25 cycles)pNL4-3228 + 142228 + 142
KOD/Adv2pNL4-391 + 57448 + 161
Phusion/Kapa HiFipNL4-3228 + 142366 + 231
Kapa HiFi/Kapa HiFipNL4-3537 + 350437 + 169

Table 3. Sensitivity of different enzyme combinations for two different samples and genes.

Values are in predicted number of copies of virus per microliter of DNA derived from endpoint dilution PCR. * SD = standard deviation.
CSV
Download CSV

Substitution errors varied up to 3-fold with different DNA polymerases

The rate of PCR error contributes to determining the sensitivity of variant detection in pyrosequencing by establishing the minimum frequency at which a true viral variant can be reliably distinguished from a PCR artifact. We therefore investigated the error rate in PCR amplification using a variety of commercially available error-correcting polymerase mixtures (Figure 1). Two different regions were amplified in the same multiplex PCR, “gagp24b” (corresponding to HXB2 positions 1576-1960) and “env5” (HXB2 7530-7974), from primer set 3. Using the small starting amounts of HIV cDNA typically available from biological samples we first attempted one round of PCR (up to 60 cycles) to amplify HIV cDNA but were unable to visualize the product on an ethidium bromide gel for the template input tested (visualization as required to calculate the number of amplifiable templates). We therefore used nested PCR to amplify sufficient levels of product.

thumbnail
Figure 1. Frequency of substitution errors for DNA polymerase combinations.

Raw data from a (A) 597bp amplicon from env and a (B) 505bp amplicon from gag. Reads were aligned to pNL4-3 and the frequency of all errors for each site are shown. The error frequency for each site was taken as the number of incorrect bases divided by the total number of reads. Each dot represents a substitution relative to the pNL4-3 consensus. Error corrected data from (C) env and (D) gag. Carry-forward errors were corrected using an in-house perl script as described in the Methods. Bars above each panel indicate which pairwise comparisons are significant at p<0.05. Pairwise comparisons were done by a Kruskal-Wallis test, with a Dunns test correction for multiple comparisons.

https://doi.org/10.1371/journal.pone.0076502.g001

Use of a high-fidelity enzyme in the first round of PCR lowered the raw error rate significantly for both amplicons (Fig. 1A,B). Using Advantage 2 in either the first round or both rounds of PCR (Adv2/Adv2), the error rates were 9.6x10-4 for gag24b and 7.4x10-4 for env 5. When Phusion was used in the first round (Phusion/Adv2) the mean error rate was lowered significantly, to 5.8x10-4 and 4.3x10-4, respectively; both p<0.05. However, using Phusion in the first round and Kapa HiFi HS in the second round lowered the mean error rate even further to 3.4x10-4 and 2.5x10-4, respectively; both p<0.05. This represents a 2.8-fold reduction for gag and a 2.9-fold reduction for env in the mean substitution error compared to Adv2/Adv2. Lowering the number of second-round PCR cycles from 35 to 25 had no effect on the error rate for Phusion/Adv2. Furthermore, for all enzymes tested there was no significant difference in the mean substitution error rates between the gagp24b and env5 amplicons.

We also processed the raw read data using an error correction pipeline that corrects for insertion/deletion (indel) and carry-forward errors [32]. After removing these errors, the substitution error for the corrected reads varied depending on the enzyme used (Figure 1C,D). The mean error rate after correction for Adv2/Adv2 was 5.4x10-4 for gagp24b and 4x10-4 for env5. For Phusion/KapaHiFi the mean error rate after correction was 3.6x10-5 and 3.4x10-5, respectively. When considering the upper 95th percentile of the error rate Adv2/Adv2 had a rate of 2.39 x10-3 and 1.9 x10-3, respectively, while the high-fidelity enzymes Phusion/Kapa HiFi had an upper 95th percentile error rate of 1.5x10-4 and 1.6x10-4, respectively (Table 4).

Mean gag (95th %ile)Mean env (95th %ile)Mean gag corrected (95th %ile)Mean env corrected (95th %ile)
Adv2/Adv20.10 (0.31)0.07 (0.28)0.05 (0.24)0.04 (0.18)
Phusion/Adv20.06 (0.15)0.04 (0.12)0.02 (0.11)0.02 (0.09)
Phusion/Adv2 (25cycles)0.05 (0.14)0.04 (0.12)0.03 (0.12)0.02 (0.09)
KOD HS/Adv20.07 (0.19)0.05 (0.13)0.03 (0.15)0.02 (0.11)
Phusion/KapaHiFi0.03 (0.09)0.03 (0.06)0.004 (0.01)0.003 (0.02)
KapaHiFi/KapaHiFi0.02 (0.07)0.02 (0.11)0.004 (0.03)0.007 (0.03)

Table 4. Mean and upper 95% percentile error cut-off for different enzyme combinations.

Numbers shown are in %. Upper 95th percentile cut-offs were chosen for determining where variants can reliably be called using different PCR enzymes.
CSV
Download CSV

Read coverage using an overlapping amplicon PCR protocol

We used an overlapping amplicon PCR protocol to attempt to improve read coverage, which can be inconsistent after DNA shearing. First-round PCR products were amplified separately using primers that targeted a 2.6kb gag-pol amplicon and a 2.1kb env gp120 amplicon. These first-round products were then pooled and subjected to a nested second-round of PCR, resulting in 11 different amplicons, six in gag-pol and five in env gp120, ranging from 391 bp to 603 bp in size. In total, we recovered sequences across 4.7 kb of the HIV-1 genome. Examples of read coverage for the 6 PIC subjects are shown in Figure 2. Regions with apparent spikes in coverage result from the overlap of amplicons generated by pooling the alignments. As expected, the two longest amplicons, gagp24a and env5 had a mean of 21.8% and 18.4% full-length reads for the seven different subjects samples tested while the shortest amplicon, pol3 had an average of 90% of reads covering the entire amplicon. To obtain full bi-directional coverage then, shorter amplicons that match with the average read length of 454 sequencing are required.

thumbnail
Figure 2. Read coverage following sequencing of amplicons derived from three regions of the viral genome from six HIV-1 infected subjects.

Eleven amplicons, representing ~4.7kb of of the viral genome were aligned to a patient specific consensus. The position of each amplicons is shown relative to the HXB2 reference genome. The “spikes” in read coverage correspond to regions in which adjacent amplicons overlap. We did not have an amplicon that spanned the region around position 2000.

https://doi.org/10.1371/journal.pone.0076502.g002

We sought to over-sequence each template in order to ensure that the observed variation was not due to errors that occurred during pyrosequencing, targeting 10 reads per template in both directions. We generated an average of 836,817 reads for each of the four plates from an average of 40,730 input molecules, for an average of 21.5 reads per template, or 10.7 reads per template in each direction.

Discussion

Massively parallel sequencing (MPS) technologies are being used to study HIV sequence variation and evolution. However, the ability to accurately detect low-frequency variants is dependent on quantitation of DNA input, low error rates in PCR, adequate read coverage, and correction of systematic errors, such as homopolymer length variation and carry-forward errors. Substantial effort has been devoted to computational methods to detect low-frequency variants. However, little has been done to lower the threshold of detection in the sample preparation steps. We sought to improve these protocols in order to identify real variants at the lowest possible frequencies.

While we compared the sensitivities of different enzymes combinations, PCR sensitivity appeared to be sample as well as enzyme dependent. Only the use of Phusion in both rounds of PCR showed a clearly lower efficiency. Additionally, our results demonstrated the shortcoming of relying on clinical viral load measurements to estimate the number of HIV templates that are being sequenced. In the patient samples evaluated here, the estimated number of copies was on average 4.7 times lower than the clinical viral load estimate (Table S1). This is attributable to the amplification of longer products (2.6 and 2.1 kb) for sequencing than the smaller fragments for clinical viral load estimates (<150bp) [8], the use of different primers and enzymes, and the possibility that the RNA was exposed to multiple freeze-thaw cycles since viral load measurements were done. Furthermore, clinical viral load assays correct for inefficiencies in extraction, reverse transcription, and PCR. The number of amplifiable templates in the PCR prior to 454 sequencing has a direct impact on detection of minor variants. Thus, clinical viral load is not a suitable measure to accurately estimate the number of amplifiable templates that are input into the PCR. Instead, it is necessary to specifically quantify the number of amplifiable templates using the same protocol, primers, amplicon length, and reaction conditions used to amplify the DNA template for MPS.

Next, we compared the error rates of different polymerases. It has previously been shown that the average mismatch error rate varies depending on enzyme used [18]. Interestingly, while there was a significant decrease in the mean mismatch error when a high fidelity DNA polymerase was used in the first round of PCR (e.g., Adv2/Adv2 vs. Phusion/Adv2), the error rate was lowered even further when a high-fidelity enzyme was used in both rounds (the best combination we tested being Phusion/KapaHiFi). This suggests that mismatch errors that occur in the 2nd round of PCR can still accumulate at significant frequencies for 454 sequencing. Site-specific error may be a more useful comparison for different enzymes rather than mean substitution error, we therefore used a cut-off at which variants can reliably be called “real” as the upper 95% percentile of the error distribution (Table 4).

Library-based pyrosequencing involves shearing of PCR fragments prior to sequencing, and is faster than amplicons sequencing because it does not rely on multiple second-round primer sets. However, lower PCR efficiency is achieved with the larger amplicons used for library-based sequencing, and shearing often results in regions of low coverage, making it difficult to consistently detect low-level variants [33]. Another study utilizing library sequencing of HIV has noted uneven read coverage [2]. The latter paper showed large disparities in read numbers between different regions as well as between samples. We were able to improve coverage consistency for pyrosequencing by utilizing an overlapping amplicon approach, although the amplicon sizes chosen for our studies were too long, as they were based on expected but unrealized extensions in read lengths from recent advances in 454 sequencing chemistries.

An advantage of the amplicon approach is that it ensures that the universal adaptors A and B are properly incorporated onto each end of the amplicons, eliminating the need to select for DNA fragments with adaptors A and B in library preparation. It also permits the use of random bar codes onto template molecules to permit derivation of consensus sequences free of PCR and pyrosequencing errors when regions no longer than a single pyrosequencing read is being evaluated [23,24].

Although we addressed PCR mismatch error, we did not examine the role of reverse transcription of RNA into cDNA. Reverse transcriptases have higher inherent error than DNA polymerases [34], and a mismatch at that stage will be scored as real variation because it occurs in the template introduced into the PCR.

The impact of minor variants on disease progression and HIV evolution is controversial. In drug resistance studies, some have reported an association between minor variants and poor clinical outcome [35-40], while others have found no such association [41-44]. Another important application of MPS is for the detection of minor variants in acute HIV infection, and possibility of early evolution resulting from immune selection pressure as detectable viremia emerges [27]. Studies utilizing deep sequencing to study immune evasion have detected escape variants not found by Sanger sequencing that occur earlier and with greater complexity [1,2,45-47]. More work is needed to understand the significance of minor variants in HIV-1 evolution and clinical progression, and the protocols described herein will enhance our ability to probe diverse sequence populations more deeply.

Supporting Information

Table S1.

Sample characteristics and sequencing of viral genome segments from 7 subjects.

https://doi.org/10.1371/journal.pone.0076502.s001

(DOCX)

Acknowledgments

The authors would like to thank Dr. Morgane Rolland and Ms. Eleanor Casey for helpful discussions.

Author Contributions

Conceived and designed the experiments: BBL LC LMF JIM. Performed the experiments: LC MK HZ DW IB. Analyzed the data: BBL BSM WD JIM. Contributed reagents/materials/analysis tools: BSM WD. Wrote the manuscript: BBL LC JIM.

References

  1. 1. Fischer W, Ganusov VV, Giorgi EE, Hraber PT, Keele BF et al. (2010) Transmission of single HIV-1 genomes and dynamics of early immune escape revealed by ultra-deep sequencing. PLOS ONE 5: e12303. doi:https://doi.org/10.1371/journal.pone.0012303. PubMed: 20808830.
  2. 2. Henn MR, Boutwell CL, Charlebois P, Lennon NJ, Power KA et al. (2012) Whole genome deep sequencing of HIV-1 reveals the impact of early minor variants upon immune recognition during acute infection. PLOS Pathog 8: e1002529. PubMed: 22412369.
  3. 3. Buzón MJ, Codoñer FM, Frost SD, Pou C, Puertas MC et al. (2011) Deep molecular characterization of HIV-1 dynamics under suppressive HAART. PLOS Pathog 7: e1002314. PubMed: 22046128.
  4. 4. Hedskog C, Mild M, Jernberg J, Sherwood E, Bratt G et al. (2010) Dynamics of HIV-1 quasispecies during antiviral treatment dissected using ultra-deep pyrosequencing. PLOS ONE 5: e11345. doi:https://doi.org/10.1371/journal.pone.0011345. PubMed: 20628644.
  5. 5. Lataillade M, Chiarella J, Yang R, DeGrosky M, Uy J et al. (2012) Virologic failures on initial boosted-PI regimen infrequently possess low-level variants with major PI resistance mutations by ultra-deep sequencing. PLOS ONE 7: e30118. doi:https://doi.org/10.1371/journal.pone.0030118. PubMed: 22355307.
  6. 6. Campbell MS, Mullins JI, Hughes JP, Celum C, Wong KG et al. (2011) Viral linkage in HIV-1 seroconverters and their partners in an HIV-1 prevention clinical trial. PLOS ONE 6: e16986. doi:https://doi.org/10.1371/journal.pone.0016986. PubMed: 21399681.
  7. 7. Redd AD, Collinson-Streng A, Martens C, Ricklefs S, Mullis CE et al. (2011) Identification of HIV superinfection in seroconcordant couples in Rakai, Uganda, by use of next-generation deep sequencing. J Clin Microbiol 49: 2859-2867. doi:https://doi.org/10.1128/JCM.00804-11. PubMed: 21697329.
  8. 8. Mulder J, McKinney N, Christopherson C, Sninsky J, Greenfield L et al. (1994) Rapid and simple PCR assay for quantitation of human immunodeficiency virus type 1 RNA in plasma: Application to acute retroviral infection. J Clin Microbiol 32: 292-300. PubMed: 8150937.
  9. 9. Palmer S, Wiegand AP, Maldarelli F, Bazmi H, Mican JM et al. (2003) New real-time reverse transcriptase-initiated PCR assay with single-copy sensitivity for human immunodeficiency virus type 1 RNA in plasma. J Clin Microbiol 41: 4531-4536. doi:https://doi.org/10.1128/JCM.41.10.4531-4536.2003. PubMed: 14532178.
  10. 10. Rodrigo AG, Goracke PC, Rowhanian K, Mullins JI (1997) Quantitation of target molecules from polymerase chain reaction-based limiting dilution assays. AIDS Res Hum Retroviruses 13: 737-742. doi:https://doi.org/10.1089/aid.1997.13.737. PubMed: 9171217.
  11. 11. Liu SL, Rodrigo AG, Shankarappa R, Learn GH, Hsu L et al. (1996) HIV quasispecies and resampling. Science 273: 415-416. doi:https://doi.org/10.1126/science.273.5274.415. PubMed: 8677432.
  12. 12. Mallona I, Weiss J, Egea-Cortines M (2011) pcrEfficiency: a Web tool for PCR amplification efficiency prediction. BMC Bioinformatics 12: 404. doi:https://doi.org/10.1186/1471-2105-12-404. PubMed: 22014212.
  13. 13. Astrovskaya I, Tork B, Mangul S, Westbrooks K, Măndoiu I et al. (2011) Inferring viral quasispecies spectra from 454 pyrosequencing reads. BMC Bioinformatics 12 Suppl 6: S1. doi:https://doi.org/10.1186/1471-2105-12-S2-S1. PubMed: 21989211.
  14. 14. Macalalad AR, Zody MC, Charlebois P, Lennon NJ, Newman RM et al. (2012) Highly sensitive and specific detection of rare variants in mixed viral populations from massively parallel sequence data. PLOS Comput Biol 8: e1002417. PubMed: 22438797.
  15. 15. Prosperi MC, Salemi M (2012) QuRe: software for viral quasispecies reconstruction from next-generation sequencing data. Bioinformatics 28: 132-133. doi:https://doi.org/10.1093/bioinformatics/btr627. PubMed: 22088846.
  16. 16. Quince C, Lanzén A, Curtis TP, Davenport RJ, Hall N et al. (2009) Accurate determination of microbial diversity from 454 pyrosequencing data. Nat Methods 6: 639-641. doi:https://doi.org/10.1038/nmeth.1361. PubMed: 19668203.
  17. 17. Zagordi O, Bhattacharya A, Eriksson N, Beerenwinkel N (2011) ShoRAH: estimating the genetic diversity of a mixed sample from next-generation sequencing data. BMC Bioinformatics 12: 119. doi:https://doi.org/10.1186/1471-2105-12-119. PubMed: 21521499.
  18. 18. Vandenbroucke I, Van Marck H, Verhasselt P, Thys K, Mostmans W et al. (2011) Minor variant detection in amplicons using 454 massive parallel pyrosequencing: experiences and considerations for successful applications. BioTechniques 51: 167-177. PubMed: 21906038.
  19. 19. Gilles A, Meglécz E, Pech N, Ferreira S, Malausa T et al. (2011) Accuracy and quality assessment of 454 GS-FLX Titanium pyrosequencing. BMC Genomics 12: 245. doi:https://doi.org/10.1186/1471-2164-12-245. PubMed: 21592414.
  20. 20. Becker EA, Burns CM, León EJ, Rajabojan S, Friedman R et al. (2012) Experimental analysis of sources of error in evolutionary studies based on Roche/454 pyrosequencing of viral genomes. Genome Biol Evol 4: 457-465. doi:https://doi.org/10.1093/gbe/evs029. PubMed: 22436995.
  21. 21. Gianella S, Delport W, Pacold ME, Young JA, Choi JY et al. (2011) Detection of minority resistance during early HIV-1 infection: natural variation and spurious detection rather than transmission and evolution of multiple viral variants. J Virol 85: 8359-8367. doi:https://doi.org/10.1128/JVI.02582-10. PubMed: 21632754.
  22. 22. Varghese V, Wang E, Babrzadeh F, Bachmann MH, Shahriar R et al. (2010) Nucleic acid template and the risk of a PCR-Induced HIV-1 drug resistance mutation. PLOS ONE 5: e10992. doi:https://doi.org/10.1371/journal.pone.0010992. PubMed: 20539818.
  23. 23. Jabara CB, Jones CD, Roach J, Anderson JA, Swanstrom R (2011) Accurate sampling and deep sequencing of the HIV-1 protease gene using a Primer ID. Proc Natl Acad Sci U S A 108: 20166-20171. doi:https://doi.org/10.1073/pnas.1110064108. PubMed: 22135472.
  24. 24. Schmitt MW, Kennedy SR, Salk JJ, Fox EJ, Hiatt JB et al. (2012) Detection of ultra-rare mutations by next-generation sequencing. Proc Natl Acad Sci U.S.A. PubMed: 22853953.
  25. 25. Knierim E, Lucke B, Schwarz JM, Schuelke M, Seelow D (2011) Systematic comparison of three methods for fragmentation of long-range PCR products for next generation sequencing. PLOS ONE 6: e28240. doi:https://doi.org/10.1371/journal.pone.0028240. PubMed: 22140562.
  26. 26. Buchbinder SP, Mehrotra DV, Duerr A, Fitzgerald DW, Mogg R et al. (2008) Efficacy assessment of a cell-mediated immunity HIV-1 vaccine (the Step Study): a double-blind, randomised, placebo-controlled, test-of-concept trial. Lancet 372: 1881-1893. doi:https://doi.org/10.1016/S0140-6736(08)61591-3. PubMed: 19012954.
  27. 27. Rolland M, Tovanabutra S, deCamp AC, Frahm N, Gilbert PB et al. (2011) Genetic impact of vaccination on breakthrough HIV-1 sequences from the STEP trial. Nat Med 17: 366-371. doi:https://doi.org/10.1038/nm.2316. PubMed: 21358627.
  28. 28. Adachi A, Gendelman HE, Koenig S, Folks T, Willey R et al. (1986) Production of acquired immunodeficiency syndrome-associated retrovirus in human and nonhuman cells transfected with an infectious molecular clone. J Virol 59: 284-291. PubMed: 3016298.
  29. 29. Schacker T, Collier AC, Hughes J, Shea T, Corey L (1996) Clinical and epidemiologic features of primary HIV infection. Ann Intern Med 125: 257-264. doi:https://doi.org/10.7326/0003-4819-125-4-199608150-00001. PubMed: 8678387.
  30. 30. Altschul SF, Gish W, Miller W, Myers EW, Lipman DJ (1990) Basic local alignment search tool. J Mol Biol 215: 403-410. doi:https://doi.org/10.1016/S0022-2836(05)80360-2. PubMed: 2231712.
  31. 31. Taswell C (1981) Limiting dilution assays for the determination of immunocompetent cell frequencies. I. Data analysis. J Immunol 126: 1614-1619. PubMed: 7009746.
  32. 32. Deng W, Maust BS, Westfall DH, Chen L, Zhao H et al. (2013) Indel and Carryforward Correction (ICC): A new analysis approach for processing 454 pyrosequencing data. Bioinformatics (. (2013)) PubMed: 23900188.
  33. 33. Iyer S, Bouzek H, Deng W, Larsen BB, Casey E et al. (2013) Quality score based identification and correction of pyrosequencing errors. PLOS ONE 8(9): e73015
  34. 34. Roberts JD, Bebenek K, Kunkel TA (1988) The accuracy of reverse transcriptase from HIV-1. Science 242: 1171-1173. doi:https://doi.org/10.1126/science.2460925. PubMed: 2460925.
  35. 35. Balduin M, Oette M, Däumer MP, Hoffmann D, Pfister HJ et al. (2009) Prevalence of minor variants of HIV strains at reverse transcriptase position 103 in therapy-naïve patients and their impact on the virological failure. J Clin Virol 45: 34-38. doi:https://doi.org/10.1016/j.jcv.2009.03.002. PubMed: 19375978.
  36. 36. Geretti AM, Fox ZV, Booth CL, Smith CJ, Phillips AN et al. (2009) Low-frequency K103N strengthens the impact of transmitted drug resistance on virologic responses to first-line efavirenz or nevirapine-based highly active antiretroviral therapy. J Acquir Immune Defic Syndr 52: 569-573. doi:https://doi.org/10.1097/QAI.0b013e3181ba11e8. PubMed: 19779307.
  37. 37. Johnson JA, Li JF, Wei X, Lipscomb J, Irlbeck D et al. (2008) Minority HIV-1 drug resistance mutations are present in antiretroviral treatment-naïve populations and associate with reduced treatment efficacy. PLOS Med 5: e158. doi:https://doi.org/10.1371/journal.pmed.0050158. PubMed: 18666824.
  38. 38. Metzner KJ, Giulieri SG, Knoepfel SA, Rauch P, Burgisser P et al. (2009) Minority quasispecies of drug-resistant HIV-1 that lead to early therapy failure in treatment-naive and -adherent patients. Clin Infect Dis 48: 239-247. doi:https://doi.org/10.1086/595703. PubMed: 19086910.
  39. 39. Paredes R, Lalama CM, Ribaudo HJ, Schackman BR, Shikuma C et al. (2010) Pre-existing minority drug-resistant HIV-1 variants, adherence, and risk of antiretroviral treatment failure. J Infect Dis 201: 662-671. PubMed: 20102271.
  40. 40. Simen BB, Simons JF, Hullsiek KH, Novak RM, Macarthur RD et al. (2009) Low-Abundance Drug-Resistant Viral Variants in Chronically HIV-Infected, Antiretroviral Treatment-Naive Patients Significantly Impact Treatment Outcomes. J Infect Dis 199: 693-701. doi:https://doi.org/10.1086/596736. PubMed: 19210162.
  41. 41. Jakobsen MR, Tolstrup M, Søgaard OS, Jørgensen LB, Gorry PR et al. (2010) Transmission of HIV-1 drug-resistant variants: prevalence and effect on treatment outcome. Clin Infect Dis 50: 566-573. doi:https://doi.org/10.1086/650001. PubMed: 20085464.
  42. 42. Metzner KJ, Rauch P, von Wyl V, Leemann C, Grube C et al. (2010) Efficient suppression of minority drug-resistant HIV type 1 (HIV-1) variants present at primary HIV-1 infection by ritonavir-boosted protease inhibitor-containing antiretroviral therapy. J Infect Dis 201: 1063-1071. doi:https://doi.org/10.1086/651136. PubMed: 20196655.
  43. 43. Peuchant O, Thiébaut R, Capdepont S, Lavignolle-Aurillac V, Neau D et al. (2008) Transmission of HIV-1 minority-resistant variants and response to first-line antiretroviral therapy. AIDS 22: 1417-1423. doi:https://doi.org/10.1097/QAD.0b013e3283034953. PubMed: 18614864.
  44. 44. Stekler JD, Ellis GM, Carlsson J, Eilers B, Holte S et al. (2011) Prevalence and impact of minority variant drug resistance mutations in primary HIV-1 infection. PLOS ONE 6: e28952. doi:https://doi.org/10.1371/journal.pone.0028952. PubMed: 22194957.
  45. 45. Bimber BN, Burwitz BJ, O’Connor S, Detmer A, Gostick E et al. (2009) Ultradeep pyrosequencing detects complex patterns of CD8+ T-lymphocyte escape in simian immunodeficiency virus-infected macaques. J Virol 83: 8247-8253. doi:https://doi.org/10.1128/JVI.00897-09. PubMed: 19515775.
  46. 46. Bimber BN, Dudley DM, Lauck M, Becker EA, Chin EN et al. (2010) Whole-genome characterization of human and simian immunodeficiency virus intrahost diversity by ultradeep pyrosequencing. J Virol 84: 12087-12092. doi:https://doi.org/10.1128/JVI.01378-10. PubMed: 20844037.
  47. 47. Love TM, Thurston SW, Keefer MC, Dewhurst S, Lee HY (2010) Mathematical modeling of ultradeep sequencing data reveals that acute CD8+ T-lymphocyte responses exert strong selective pressure in simian immunodeficiency virus-infected macaques but still fail to clear founder epitope sequences. J Virol 84: 5802-5814. doi:https://doi.org/10.1128/JVI.00117-10. PubMed: 20335256.