Skip to main content
Advertisement
Browse Subject Areas
?

Click through the PLOS taxonomy to find articles in your field.

For more information about PLOS Subject Areas, click here.

  • Loading metrics

Prediction of Nociceptive Responses during Sedation by Linear and Non-Linear Measures of EEG Signals in High Frequencies

  • Umberto Melia ,

    umberto.melia@upc.edu

    Affiliations Dept. ESAII, Universitat Politècnica de Catalunya, Pau Gargallo 5, 08028, Barcelona, Spain, Centre for Biomedical Engineering Research, Pau Gargallo 5, 08028, Barcelona, Spain, CIBER-BBN, Pau Gargallo 5, 08028, Barcelona, Spain

  • Montserrat Vallverdú,

    Affiliations Dept. ESAII, Universitat Politècnica de Catalunya, Pau Gargallo 5, 08028, Barcelona, Spain, Centre for Biomedical Engineering Research, Pau Gargallo 5, 08028, Barcelona, Spain, CIBER-BBN, Pau Gargallo 5, 08028, Barcelona, Spain

  • Xavier Borrat,

    Affiliations Systems Pharmacology Effect Control & Modeling (SPEC-M) Research Group, Anesthesiology Department, Hospital CLINIC de Barcelona, Barcelona, Spain, Neuroimmunology Research Program Institut de Investigacions Biomèdiques August Pi Sunyer (IDIBAPS), Barcelona, Spain

  • Jose Fernando Valencia,

    Affiliation University of San Buenaventura, Dept. Electronic Engineering, Cali, Colombia

  • Mathieu Jospin,

    Affiliation R&D Dept. Quantium Medical SL, Mataró, Spain

  • Erik Weber Jensen,

    Affiliation Centre for Biomedical Engineering Research, Pau Gargallo 5, 08028, Barcelona, Spain

  • Pedro Gambus,

    Affiliations Systems Pharmacology Effect Control & Modeling (SPEC-M) Research Group, Anesthesiology Department, Hospital CLINIC de Barcelona, Barcelona, Spain, Neuroimmunology Research Program Institut de Investigacions Biomèdiques August Pi Sunyer (IDIBAPS), Barcelona, Spain, Department of Anesthesia and Perioperative Medicine, University of California San Francisco, San Francisco, California, United States of America

  • Pere Caminal

    Affiliations Dept. ESAII, Universitat Politècnica de Catalunya, Pau Gargallo 5, 08028, Barcelona, Spain, Centre for Biomedical Engineering Research, Pau Gargallo 5, 08028, Barcelona, Spain, CIBER-BBN, Pau Gargallo 5, 08028, Barcelona, Spain

Abstract

The level of sedation in patients undergoing medical procedures evolves continuously, affected by the interaction between the effect of the anesthetic and analgesic agents and the pain stimuli. The monitors of depth of anesthesia, based on the analysis of the electroencephalogram (EEG), have been progressively introduced into the daily practice to provide additional information about the state of the patient. However, the quantification of analgesia still remains an open problem. The purpose of this work is to improve the prediction of nociceptive responses with linear and non-linear measures calculated from EEG signal filtered in frequency bands higher than the traditional bands. Power spectral density and auto-mutual information function was applied in order to predict the presence or absence of the nociceptive responses to different stimuli during sedation in endoscopy procedure. The proposed measures exhibit better performances than the bispectral index (BIS). Values of prediction probability of Pk above 0.75 and percentages of sensitivity and specificity above 70% were achieved combining EEG measures from the traditional frequency bands and higher frequency bands.

Introduction

To determine appropriate requirements for administration, monitoring and control of sedation and / or analgesia in invasive medical procedures is necessary in order to minimize the impact of the aggression in the patient and the implications on the outcome of the process. Hypnotic drugs (intravenous or inhaled) are used in order to achieve an accurate level of hypnosis, while fundamentally strong opioids are used in order to achieve the desired level of analgesia. The proper implementation of proposed model to monitor the anesthetic state is based on a quantification of the pharmacological effects for reaching a perfect set respect to the requirements of each patient. This involves the development of models connected directly in real-time with physiological variables of the patient. For several years, various methods have been developed for the noninvasive assessment of the level of consciousness during general anesthesia [16]. Since the main action of anesthetic agents occurs in the brain, a reasonable choice is to monitor the electroencephalographic signal (EEG). Changes on the EEG signal are directly related to biochemical variations of a drug induced in the brain and the effects on individual behavior. For this reason, different EEG monitors have been developed [712]. Analysis of the Bispectrum of the EEG signal, entropy analysis, and auditory evoked potentials extracted from the EEG or automated neurofuzzy inference systems are some of the methods applied to the complex EEG signal to design clinically relevant indicators of hypnotic effect.

However, it has not been possible to develop a system capable of quantifying analgesia. The most used methods [1316] include hemodynamic response, analysis of electrocardiographic waveforms variability, degree of respiratory sinus arrhythmia, plethysmographic response, pulse wave, heart rate variability and skin conductance. None of them has proven to be clinically useful methods because they are influenced by the response of the autonomic nervous system (ANS) and they are sensitive to other disturbances, such as changes in blood pressure or heart rate due to patient's baseline condition (hypertension, arrhythmias of diverse etiology), sympathomimetic drug delivery or unpredictable situations such as perioperative bleeding. Recently, two studies based on time-frequency representation [17] and auto-mutual information function [18] demonstrated that changes associated to EEG spectrum and EEG complexity in the traditional bands permitted to improve the prediction of the Ramsay sedation scale (RSS) and the response to tube insertion during endoscopy procedure. However, the discrimination between deep sedation level with no response to any stimulation (RSS = 6) and sluggish response to painful stimulation (RSS = 5) still remains an open problem. Some studies indicated that the EEG-based monitors cannot reliably distinguish between light sedation and deep sedation, as these are designed to measure levels of general anesthesia that handle very different levels of hypnosis to those used in sedation procedures. Therefore still remains the need for an objective measurement to quantify the level of sedation in patients undergoing invasive procedures. Additionally, during sedation procedures patients develop a greater degree of muscular activity compared to patients undergoing general anesthesia procedures [19]. A biopotential signal measured from the forehead of a patient includes a significant EMG component, which is created by muscle activity. The EMG signal has a wide noise-like spectrum and during anesthesia typically dominates at frequencies higher than 30 Hz. Sudden appearance of EMG signal data often indicates that the patient is responding to some external stimulus, such as a painful stimulus, due to some surgical event. Such a response may result if the level of analgesia is insufficient. If stimulation continues and no additional analgesic drugs are administered, it is highly likely that the level of hypnosis starts to reduce. Thus, EMG can help to provide a rapid indication of imminent arousal [9].

In this work, we assume that the prediction of the responses to pain stimulation during endoscopy procedure can be improved by using measures calculated in the recorded EEG taking into account also the EMG frequency bands derived from scalp and facial muscles. In this sense, it might be possible to associate an increased activity in the facial muscles with a greater possibility of pain, obtaining better prediction of responsive states. To achieve our goal, linear and non-linear measures were calculated on the EEG signal in the traditional bands δ, θ, α, β and in higher frequency bands (HF: 60–95 Hz and VHF: 105–145 Hz). Several measures based on power spectral density and auto-mutual information function were defined in order to evaluate the prediction of responding to the application of painful stimuli such as nail bed compression or endoscopy tube insertion.

Materials and Methods

Database

The analyzed database belongs to the Department of Anesthesiology, Hospital Clínic of Barcelona (Spain). This database contains data recorded from 378 patients (mean age 63±23 years, 247 men) undergoing ultrasonographic endoscopy of the upper gastrointestinal tract under sedation and analgesia with propofol and remifentanil. All the patients belong to 1–3 ASA classification. Patients with altered central nervous system, medicated with analgesics or drugs with central effects on the perception of pain, from moderate to severe cardiomyopathy, neuropathy or hepatopathy that needed control during the anesthetic process were not included in the database. The study received approval from the Ethics Committee of Hospital Clinic de Barcelona and all the patients signed informed consent.

For each patient, the following information is available: predicted effect site concentrations of propofol (CeProp) and remifentanil (CeRemi); bispectral Index (BIS) and electroencephalogram (EEG) signal. The observed categorical responses after applied nociceptive stimuli include the evaluation of the RSS (see Table 1) [20] after nail bed compression and the presence of gag reflex during endoscopy tube insertion (GAG). Specifically, RSS 2, 3, 4 and 5 corresponds to a patient who responded with purposeful movement after nail bed compression while patients in the RSS 6 category did not respond. GAG corresponds to a positive nausea reflex during endoscopy tube insertion, a nociceptive stimulus as well. The RSS score was evaluated at random times during the procedure in order to avoid those factors correlated with time, which could confound the results of the RSS measurements. The whole database contains annotated RSS scores from 2 to 6.

The EEG was recorded with a sampling frequency of 900 Hz, with a resolution of 16 bits and a recording time of about 60 min using AEP monitor/2 (Danmeter, Odense, Denmark). A 3-electrode montage was used: middle forehead (+), malar bone (-), and left forehead electrode used as reference. Propofol and remifentanil were infused using a TCI system (FreseniusVial; Chemin de Fer, Béziers, France). All information CeProp, CeRemi, BIS, RSS and GAG were annotated with a resolution of 1 second.

EEG Preprocessing

The traditional bands analysis was performed on EEG signals filtered between 0.1–45 Hz and resampled at 128 Hz, while high frequency analysis was performed on EEG filtered between 0.1–145 Hz and resampled at 300 Hz. After the resampling process, the EEG signals were segmented in windows of length of 1 minute taken between 30 s and 90 s before the response annotation of RSS or GAG, in order to avoid the effect of the stimulation on the signal. The selected windows were filtered into the following frequency bands: δ, 0.1–4 Hz; θ, 4–8 Hz; α, 8–12 Hz; β, 12–30 Hz; HF; 60–95 Hz and VHF; 105–145 Hz; TB, 0.1–145 Hz. The frequencies round 50 Hz and 100 Hz were not taken into account in order to avoid the power line noise and the interferences caused by the self-test impedance device that produce a peak in the spectrum. Finite impulse response (FIR) filter of 50th order was used in the present work. The order of the FIR filter was fixed to 50 in order to ensure the attenuation and the ripple in the stop band to be less than 5%.

The annotated RSS was assigned to the previous 1 minute length window if the differences ΔCeRemi and ΔCeProp between the first and the last second of the window were ΔCeRemi<0.1 ng/ml and ΔCeProp<0.1 μg/ml. Otherwise, the window was taken till the sample where the conditions were satisfied.

Firstly, a visual analysis was performed in order to eliminate EEG recording affected by strong noise of different types. Then, windows of EEG containing high amplitude peak noise were processed with a filter based on the analytic signal envelope (ASEF) [21]. This permitted to eliminate the peak noise, preserving the EEG frequency content. The FIR filter permitted to eliminate noise that have different frequency band from EEG signal. Another algorithm were applied in order to detect if adjacent samples differ more than 10% of the mean of the previous samples differences. In that case, those samples and the subsequent ones were not taken into account. In this way, the smallest analyzed window resulted to be of 50 s.

Traditional EEG analysis

The following measures were calculated in each EEG window:

  • Standard deviation (std) of the EEG windows filtered in each band.
  • Power spectral density (PSD) for each EEG window in TB band using the Welch method.
  • Spectral power in each band (Pδ, Pθ, Pα, Pβ, PHF, PVHF) as the area under the PSD curve normalized by the total PSD area.
  • Weighted mean frequency (mF) in each band (TB, δ, θ, α, β, HF, VHF) as the centroid of the PSD curve.
  • Spectral edge frequencies SEF50, SEF75 and SEF90 in each band.
  • Autocorrelation function (Ac)

The PSD was computed using Welch’s method of averaged modified periodograms. EEG segments were divided into one-second segments with 25% of overlap; Hamming window was applied to each segment. The final spectral density was achieved as the average of spectral densities of all the segments.

Auto-Mutual Information Measures

Mutual information (MI) can measure the nonlinear as well as linear dependence of two variables. It is a metric derived from Shannon’s information theory to estimate the information gained from observations of one random event on another [22,23]. Usually, MI is measured between two different systems X and Y. Let X and Y be discrete random variables which take a finite number of possible values xi and yj with probabilities Px(xi) and Py(yj) respectively, ≥ 0, i = 1, 2, 3…n and j = 1, 2, 3…n, MI between X and Y is given by [22,23]

(1)

Auto-mutual information function (AMIF) (2) is calculated as the MI between two measurements xi and xi+τ taken from a single time series.

(2)

AMIF function describes how the information of a signal (AMIF value at τ = 0) decreases over a prediction time interval (AMIF values τ>0). Increasing information loss is related to decreasing predictability, and increasing complexity of the signal [24].

AMIF can be also defined from Rényi entropy as (3) where q is the control parameter of Rényi entropy.

In Eq (3), the largest probabilities most influence the AMIF_Req when q>1 and the smallest probabilities most influence the values of AMIF_Req when 0<q<1. The AMIF_Req converge to the Shannon AMIF when q → 1. In this work, different values of the control parameter of Re: q = {0.1, 0.2, 0.5, 2, 3, 5, 10, 30, 50, 100} were taken into account.

The probabilities Pxy, Px and Py were constructed on the series xi or yj and their delayed series xi+τ or yj+τ for τ = {1,2,…,300} samples. The amplitude range of the data series was quantized using 32 equidistant partitions. This made the maximum possible value of AMIF equal to log2 32 = 5 bits. The number of bins was fixed following the recommendation of a previous work [25] which demonstrated that AMIF indexes applied to EEG were more stable and showed the less variability using 32 partitions. The τ limit was fixed to 300 samples that correspond to 1 s in order to find a compromise between the considered EEG frequency bands, the non-stationary characteristics of the EEG and the computing time. In this way, also the lowest frequency band (δ = 0.1–4 Hz) could be explored with a significant sample resolution (τδ> fs/ fδ, fs = 300 Hz, fδ <4 Hz: τδ >75 samples). Furthermore, the assumption of the EEG signal stationarity is ensured in the time delay of τ = 1 s and a reasonable computational cost is guaranteed.

The q range was chosen in order to have a distribution of q<1, q = 1 and q>1 values. Previous studies [26,18] demonstrated that AMIF has significantly changes if those partitions of q were taken into account and that the statistical results did not change in a significantly way in the range 50>q>100. We recognize that it would be more interesting and useful to analyze a fine partition of q values. However, the optimization of q value for AMIF would involve further analysis that are out of the purpose of this study. This can be considered as a future step in order to optimize the performance of a clinical indexes based on AMIF.

AMIF was normalized by the maximum value (AMIF(0)).

Data Analysis

The AMIF function was analyzed with respect to τ in order to define measures able to discriminate between RSS scores. Then, several tests were performed on the EEG measures focusing on the discrimination between no-response (RSS = 6), sluggish responses (RSS = 5) and stronger responses (RSS<5). Firstly, EEG windows associated with sluggish responses (RSS = 5) were compared with no-responses (RSS = 6) in order to find measures that can—distinguish between adjacent sedation levels, trial1. Then, EEG windows associated with unresponsive states (RSS = 6), were compared with windows associated to all the responsive states (RSS<6), trial2, in order to discriminate between unresponsive and all the responsive states. In the following RSS tests, the measures calculated on EEG windows associated with the stronger stimuli responses (RSS<5) were compared with sluggish responses (RSS = 5), trial3, then with no-responses (RSS = 6), trial4, and finally with both sluggish and no-responses (RSS≥5), trial5. These last trials might help to improve the discrimination between stronger responses associated with low sedation levels and sluggish and no-responses associated with deeper sedation levels. In all the trials the unresponsive state is caused by an interaction between hypnotic and analgesic effects, while the responsive states are characterized by an insufficient presence of analgesic effect in the drug combination administered, especially when 2≤RSS<5.

Finally, the proposed variables that gave the highest Sen, Spe and Pk in the RSS prediction were used in GAG assessment, in order to evaluate their applicability on the prediction of the response to a different type of stimulus.

Statistical Analysis

The U of Mann-Whitney test, was applied and a significance level p-value <0.05 was taken into account. Bonferroni correction was applied in case of multivariate comparison. Measures that showed statistical significance were considered for building univariable and multivariable discriminant functions.

The leaving-one-out method was performed as validation. Sensitivity (Sen) was used to measure the ratio between correctly classified windows associated with pain responses (RSS<6 and GAG 1) and the whole number of windows associated with pain responses; while specificity (Spe) was used to measure the ratio between correctly classified windows associated with no response (RSS = 6 and GAG 0) and the whole number of windows associated with no response.

The ability of the variables to describe pain responses was also evaluated using prediction probability (Pk), a statistic commonly used to compare the performance of indicators [27]. The standard error (SE) of the estimated Pk was also calculated in order to assess its accuracy. For the comparison between the Pk values obtained from the BIS and the EEG measures, a T-Student with significance level of 5% was performed. In order to build the multivariate model, an algorithm of feature selection was developed and applied to all the calculated measures that showed statistical significance (p-value<0.05) in at least one of the trial. The algorithm randomly selects a maximum of 4 not correlated measures and performed the multivariable discriminant analysis. More than 1000 iterations of the algorithm were performed in order to maximize the Pk under the condition of both Sen and Spe >60%. The best obtained combination are shown in the results section.

Results

As examples, Figs 1 and 2 show the averaged functions AMIF_Re05(τ) in VHF band and AMIF_Re50(τ) in θ band for different RSS levels, these two functions gave the most significant results in this first analysis. The τ delays in which those functions were able to yield p-value <0.05 and Pk>0.7 when discriminating between RSS<6 and RSS = 6, between RSS = 5 and RSS = 6, between RSS<5 and RSS = 5 and between RSS<5 and RSS = 6 are also represented. As it can be noted from Fig 1 and Fig 2, AMIF profiles exhibited an initial fast decrease at short time scale followed by a slow increase, then they decreased to nonzero stable values at longer time scales. Comparing RSS<6 and RSS = 6, few differences at short time-scale can be observed in VHF band (Fig 1A and Fig 1B) and at long time-scale in θ band (Fig 2A and Fig 2B), denoting different complexity behavior. Several statistical differences between RSS<5 and RSS = 5 or RSS = 6 are observed in θ band (Fig 2C and Fig 2D) both at short and long time-scales. From this first analysis it was deduced that the most appropriate measures with respect to delay τ that might quantify and extract the essential information contained on AMIF were: mean (m), first relative maximum (maxL), absolute minimum (min), and first decay (FD). The FD measure was calculated as the difference between the AMIF(0) and the AMIF(1). In this way, the values of the AMIF measures describe the complexity of the EEG signal: higher values of m, maxL and min are associated with less complexity, more regularity of the signal; contrarily higher values of FD are associated with more complexity and more irregularity of the signal. The same measures applied to AMIF were calculated on Ac. The EEG measures calculated on AMIF and PSD are summarized in Fig 3.

thumbnail
Fig 1. Auto-Mutual Information Function (AMIF).

Averaged AMIF functions in VHF (105–145 Hz) band q = 0.5 of all windows of (a) RSS<6 and RSS = 6, (b) RSS = 5 and RSS = 6, (c) RSS<5 and RSS = 5, (d) RSS<5 and RSS = 6. The p-values were corrected using Bonferroni equation.

https://doi.org/10.1371/journal.pone.0123464.g001

thumbnail
Fig 2. Auto-Mutual Information Function (AMIF).

Averaged AMIF functions in θ band q = 50 of all windows of (a) RSS<6 and RSS = 6, (b) RSS = 5 and RSS = 6, (c) RSS<5 and RSS = 5, (d) RSS<5 and RSS = 6. The p-values were corrected using Bonferroni equation.

https://doi.org/10.1371/journal.pone.0123464.g002

thumbnail
Fig 3. Measures extracted from Auto-Mutual Information Function (AMIF) and Power spectral density (PSD).

Example of the measure calculation from (a) AMIF and (b) PSD.

https://doi.org/10.1371/journal.pone.0123464.g003

Fig 4 shows the values of the measures that gave the highest Sen, Spe and Pk in both univariable and multivariable discriminant functions.

thumbnail
Fig 4. Values of EEG Measures with Ramsey score (RSS).

Distribution of the values of (a) first decay of Auto-Mutual Information Function (AMIF) in VHF (105–145 Hz) band for q = 0.2, (b) first decay of AMIF in VHF (105–145 Hz) band for q = 0.5, (c) weighted mean frequency in α band, (d) mean value of AMIF in θ band for q = 50, (e) power spectral density in β band, (f) power spectral density in VHF (105–145 Hz) band. On each box, the central mark is the median; the edges of the box are the 25th and 75th percentiles. The whiskers are lines extending from each end of the boxes to show the extent of the rest of the data. Values beyond the end of the whiskers are considered outliers and marked with a +.

https://doi.org/10.1371/journal.pone.0123464.g004

From Fig 4 it can be noticed that when smallest probabilities predominate (q = 0.2, q = 0.5), RSS = 6 presents less complexity behavior than RSS = 5 in VHF (Fig 4A and 4B). The weighted mean frequency in α band is lower for RSS = 6 (Fig 4D) than RSS = 5. Furthermore, it can be observed that EEG windows of RSS<5 present less complexity behavior in θ band and higher power in β band than windows of RSS = 5 and RSS = 6.

Table 2 shows the results of the measures that gave the highest Sen, Spe and Pk using univariate discriminant function in trial 1 and trial 2. It can be noted that measures of AMIF in VHF are able to discriminate between RSS = 5 and RSS = 6 with Sen, Spe and Pk higher than BIS (T-student test, p-value<0.0001). However, only measures in VHF band permitted to discriminate between RSS = 5 and RSS = 6 with Pk>0.7.

Table 3 shows the results of the measures that gave the highest Sen, Spe and Pk using multivariate discriminant function in trial 1 and trial 2. The combination of four measures permitted to yield Sen, Spe and Pk higher than BIS (T-student test, p-value<0.01) when discriminating between RSS<6 and RSS = 6. Table 4 shows the results of the measures that gave the highest Sen, Spe and Pk using multivariable discriminant function in trial 3, 4 and 5.

Table 5 shows the results of the prediction of GAG using the variables that gave the highest Sen, Spe and Pk in the previous trials. In general, combination of measures capable to discriminate between RSS<5 and RSS≥5 gave high discrimination performances in GAG assessment. The combination between mFα, FD(Re05)VHF, maxL(Re2)HF, min(Re30)δ gave the highest performances in the discrimination between RSS = 5 and RSS = 6 (Pk> 0.75, Sen and Spe >70%) and yield Pk>0.8 in the discrimination between RSS<6 and RSS = 6. However, it was not able to predict the GAG responses (Pk<0.7). The combination between m(Re50)θ, Pβ, PVHF, FD(Re05)VHF yielded Pk>0.75 in all the trials and in the GAG prediction.

thumbnail
Table 5. GAG assessment: multi-variable discrimination between EEG windows taken 30 s before the tube insertion: absence (GAG = 0) and presence of gag reflex.

https://doi.org/10.1371/journal.pone.0123464.t005

As an example, Fig 5 shows the evolution of BIS, CeRemi, CePropo, m(Re50)θ, Pβ, PVHF, FD (Re02)VHF and FD (Re05)VHF with respect to the entire recording time; the RSS annotation and the tube insertion are also shown. The EEG measures were calculated by sliding 60 s windows with steps of 1 s. As it can be noted, Pβ, PVHF FD (Re02)VHF and FD(Re05)VHF values are lower in the central part of the recording, when RSS = 6, while they increase when RSS<6. This implies less power and less complexity in high frequencies when the level of sedation is higher. The trend of m(Re50)θ denotes higher complexity in θ band for unresponsive state compared with RSS<5.

thumbnail
Fig 5. Time evolution of EEG measures.

Example of time-evolution of bispectral index (BIS), predicted effect site remifentanil (CeRemi (ng/ml)) and propofol (CePropo (μg/ml)), mean value of AMIF in θ band for q = 50, power spectral density in β band, power spectral density in VHF (105–145 Hz) band, first decay of Auto-Mutual Information Function (AMIF) in VHF (105–145 Hz) band for q = 0.5 and first decay of AMIF in VHF (105–145 Hz) band for q = 0.2 of a patient entire recording. All the EEG measures are represented in arbitrary units. Black vertical line represents the tube insertion, GAG = 1 in the first insertion and GAG = 0 in the second insertion. RSS annotation are represented with yellow (RSS = 2), pink (RSS = 3), purple (RSS = 4), blue (RSS = 5) and red (RSS = 6) circles.

https://doi.org/10.1371/journal.pone.0123464.g005

Discussion

The proposed work reported a methodology for the prediction of pain responses during sedation based on EEG filtered in the traditional frequency bands and in higher frequency bands. In general, the combination of four measures in the traditional EEG bands is enough to yield Pk>0.8 when discriminating between RSS<5 and RSS≥5 (Table 4) and when predicting the gag reflex (Table 5). However, when discriminating between RSS<6 and RSS = 6 or between RSS = 5 and RSS = 6, only by using measures from EEG filtered at high frequency bands (HF; 60–95 Hz and VHF; 105–145 Hz) values ofPk>0.75 are obtained. In all the trials combinations of four EEG measures yielded discrimination performances better than BIS (T-student test, p-value<0.0001) in the prediction of pain responses. It is worth noting that the BIS index integrates several EEG measures such as time domain, frequency domain, and high order spectral parameters into a single variable. In this way, in order to make an appropriate comparison between the BIS and the results of the present study, the multi-variable analysis of EEG measures should be taken into account. However, it can be noted that, when discriminating between RSS = 5 and RSS = 6,BIS is outperformed by single measures calculated on EEG filtered in VHF (Table 2). It is well known that BIS is able to describe hypnotic effect as it is confirmed by results of trial 2, 4 and 5, since the responsive states of these trials is characterized by an insufficient presence of analgesic effect in the drug combination administered. In this case, the discrimination is performed between sedation levels characterized by different hypnotic states at low analgesic effect. However, as it was seen in trial 1, 3 and GAG the proposed multi variable functions showed a better capability than BIS to describe the analgesic effect. The presence of analgesic, remifentanil in this case, causes that the patient can not react to painful stimuli even with a low level of hypnotic agents (i.e. a high BIS value). If, instead of analgesic, only propofol were dispensed, its concentration would have to be higher in order to block painful stimuli and that would produce very low BIS values. The hardest challenge is the discrimination between sluggish response (RSS = 5) and no response (RSS = 6). In general, the major benefits in the discrimination of these two RSS levels were provided by studying changes in the power spectral density in α and β bands of EEG and in the complexity behavior of EEG filtered in high frequency band (60–95 Hz and 105–145 Hz). In order to yield high performances in the prediction of different stimuli responses, the complexity behavior of δ and θ bands and the power spectral density in VHF should also be taken into account.

In a previous work, spontaneous frontal electromyography (SEMG) has been shown to be a useful indicator of pending arousal [28]. Another study demonstrated that sudden increases in the amplitude of SEMG activity in frontal muscles during surgery indicated enhanced patient responsiveness [29]. This is due to the motor innervation of the upper facial muscles, which arises from the brainstem, with connections to vigilance centers in the reticular formation. Some successful applications of the SEMG on the detection of arousal during anaesthesia have been published [2830]. However, due to great inter-individual variability in the amplitude of the SEMG, this technique has not gained wide clinical acceptance. In this work, the AMIF computation normalized by the maximum value permits to obtain non-linear measures that might limit the inter-individual variability.

Recently, Mathews et al. [31] showed that measures of electroencephalogram and EMG variability increased when intraoperative somatic events occurred and permitted to discriminate between 10-minute segments that contained a somatic event and those segments that did not contain an event. Their results have been demonstrated to be better than the methods based on changes in HR and mean arterial blood pressure. The contraction strength of a frontals muscle is linearly dependent on the firing rate of motoneurons, which innervate the frontals. As surface electrodes measure the sum of signals from multiple motor units, the work of Rautee et al. suggested that the complexity of the SEMG band is related to the level of desynchronization between firing rates among adjacent motor units. The results of spectral entropy in that study demonstrated that increased firing rates seem to produce increased desynchronization between motor units [32] associated with higher disorder of the system. In the present work, the EEG filtered in VHF bands presents less complexity in RSS = 6 than RSS≤5 being the value of the AMIF first decay lower (Fig 4A and 4B). In this way, the less complexity behavior of the EEG filtered at VHF might be associated with a decrease of the firing rates of the SEMG induced by the deeper level of sedation. This is corroborated by the lower values of the power in VHF observed in unresponsive states (Fig 4F) and in the central part of the time evolution in Fig 5.

Regarding the traditional EEG bands, previous studies have been demonstrated that increased sedation levels are marked by increased δ and θ power and frontal α with increased peak frequency [3336]. Then, increasing propofol concentration in human subjects shifts cortical activity from a high-frequency, low-amplitude signal to a low-frequency, high-amplitude signal. Specifically, β activity decreases and α and δ activities increase [37] with increasing levels of propofol anesthesia. In Fig 4E it can be observed that Pβ is lower for the unresponsive state reflecting a higher level of sedation respect unresponsive states. Also the weighted mean frequency in α band (Fig 4C) is lower for RSS = 6, this implies that the spectral power is higher in lower frequencies. In this work, patients in deep sedation showed a more complex EEG activity in low frequency bands than patients in lower sedation levels (Fig 4D). This can be related with the fact that EEG activity becomes slower as the sedation level increases, and thus, it is expected that patients in unresponsive state present a slower EEG signal than responsive state, increasing the signal complexity in low frequency bands. Power in the high-frequency component of EEG signals corresponds to corticocortical activity [37], while power in the low-frequency component of EEG signals primarily arises from subcortical interactions [38]. The decrease in high-frequency power with the administration of propofol may be due to a decrease in intracortical and corticocortical activity. The increase in low-frequency power may arise from interactions with subcortical structures such as the thalamus [36, 39]. EMG activity reflects subcortical activity during general anaesthesia. According to previous studies, subcortical structures could be a site of the analgesic effect of anaesthetics [4042].

Most studies addressing mechanisms of sedation and consciousness have been performed under the effects of one drug only being it propofol or sevoflurane. Addition of an opioid as in this case might probably affect the mechanisms of sedation in several ways but by the analysis of the EEG collected in our study it is not possible to establish a mechanistic hypothesis other than the already demonstrated synergy between opioids and hypnotic drugs.

To our knowledge, there are not many publications addressing this topic of sedation-analgesia under combined propofol and remifentanil in real patients. One of them [43] have different RSS score target (RSS = 4) and another one only took into account the drug concentration for studying the loss of response [44] in volunteers undergoing a process similar to gastrointestinal endoscopy.

In previous studies, all the EEG derived indexes showed high statistical performances in the detection of the deep of anesthesia [4546] with correlation scores or Pk >0.8.

However, general anesthesia requires deeper levels of hypnotic and opioid concentrations, most of the times with pharmacological muscular paralysis to allow for mechanical ventilation that eliminates any muscular activity improving the ability to predict certain responses with the EEG because it is free of EMG signal.

During sedation and analgesia patients must be comfortable, painless but breathing spontaneously. This means that there will be muscular activity. EEG derived measure such as BIS will perform worse in this context as demonstrated by the results of the present work. A measure that would take into account EMG activity by expanding the frequency spectrum to be analyzed, as proposed in the present investigation, would probably be a better candidate to predict sedation states better.

Auto-Mutual information function was chosen as a non-linear technique in order to evaluate the complexity behavior of the EEG filtered in the different bands. The fundamental assumption of nonlinear techniques is that EEG signal is generated by nonlinear deterministic processes with nonlinear coupling interactions between neuronal populations [47, 48]. In general, the most applied complexity measures found in the literature are attractor dimension [49], correlation dimension [50], Lyapunov exponent [51], fractal dimension [52], entropies [52], recurrence quantification analysis [53], higher order statistic and spectral [54]. Most of the complexity measures mentioned above depend on the setting of estimation parameters, namely embedding dimension, time delay of phase space reconstruction, prediction time horizon, and partitioning signals. Assuming that the dimensional complexity of the nonlinear system that generates the EEG signals is expected to be between 5 and 10 [55, 56], depending on the aware or unaware states, the limit of the time series length was defined between 103 and 105 samples [57] or even greater than 105 [58]. These suppose a large sample size of the data while mutual information function that describes the amount of information of a signal with regard to a time shifted quantity can be constructed on short time series. This allows the AMIF data to be computed more frequently so that the overall diagnostic indicator can quickly indicate changes in the state of the patient. On the other hand, in this work mutual information requires the estimation of probabilities from limited EEG time series and this might affect the estimation of mutual information functions. However, in a previous work [59] this function was calculated using 1024 samples after demonstrating a stabilization of the mutual information measures variability for at least 512 samples. Furthermore, in other studies mutual information functions were estimated on EEG and heart beat time series with length between 103 and 104 samples [60, 61]. In the proposed work the smallest EEG window resulted to be of 50 s corresponding to 6400 samples at a sampling frequency of 128 Hz.

Furthermore, in the last decades, various time-frequency analysis methods have been proposed for analyzing, interpreting, and scoring EEG signals, such as the wavelet transform [62], the Hilbert-Huang transform (HHT) [63]. However, the wavelet transform requires the proper choice of a mother wavelet function and the HHT, which is based on empirical mode decomposition (EMD) [64], is very sensitive to the instantaneous energy content of the harmonics and depends on the chosen spline-fitting techniques and stopping criterion [65]. For this reason, the results might be perturbed [66], especially if random noise is present in the signal. In this way, before applying these methods on the present dataset further specific studies should be performed but that would be out of the purpose of this work. Furthermore, in the frequency representation provided by the wavelet transform and the HHT, there is no direct correspondence between the scale and wavelength or frequency. Also, the conversion factors that yield an approximate scale-frequency correspondence must be found. Regarding high order spectral, since this feature is already included in the bispectral index we decided to not apply it in the present study.

In this way, time-frequency representation based on Wigner-Ville and Choi-Williams distribution might be suitable for the purpose of this work for its ability to represent the spectral features at each time-instant. However, comparing the results of two previous works, applied to the same database, it can be noted that the statistical performances of the measures based on time-frequency representation [17] does not significantly improve the statistical performances of measures based on the Welch method [18]. In this way, since the Welch method avoids excessive computational charges and requires less computing time, it was considered to better fit with the purpose of this study.

In all the trials, indexes based on AMIF outperformed all the autocorrelation and spectral indexes in term of Sen, Spe and Pk. Especially, in the trial 1, only AMIF measures showed Pk>0.65, in EMG band. We assumed that the properties of AMIF to deal with non-linear dynamics permit to detect differences in complexity behavior between the EEG recorded in different sedation levels. One can say that, in the case of the present study, AMIF should not provide additional information because of the slightly presence of nonlinear dynamics in EEG signal in healthy people compared with people suffering relevant neural pathology. However, previous studies suggested the importance of nonlinear EEG analysis as a tool to monitor anesthetic depth [67, 68], since they found correlation between EEG complexity indexes and depth of anesthesia and drug concentrations. Furthermore, we supposed that in EMG frequency bands, the presence of nonlinear dynamics might be stronger than in EEG. In this way, EEG filtered in EMG frequency bands might have different complexity behavior when comparing different values of Ramsey scores.

A previous study [69] assessed that nonstationarity affect frequency and information parameters, requiring stationarity of the EEG in the application of power spectral and AMIF. However, several works demonstrated that, during wakefulness, EEG can be considered stationary for short intervals (about 1–20 s) and with increasing anaesthetic level, the probability and duration of stationary EEG increases [7074]. In the present study, the effect of non-stationarity was minimized by averaging the power spectral density calculated with Welch method using a moving window of 1 s. In this short interval, we can use the assumption of stationary EEG. Regarding the application of AMIF, a compromise has to be made between the minimum window length for estimating the probability density and EEG stationarity. To solve this issue, we applied AMIF to one-minute EEG windows and we took into account values of time delay τ lower than 1 s, in AMIF calculation. Furthermore, the EEG windows were taken into account only if no-variation higher than 0.1 ng/ml of remifentanil and 0.1 μg/ml of propofol were observed. In this way, we might assume that EEG did not have strong variations due to variation in the drug concentrations and thus the sedation level did not change. From all these considerations, we assume that, even though the analyzed window were of one-minute length, the non-stationarity effect on our results were minimized.

Analyzing all the results it can be denoted that the combinations of linear and non-linear measures calculated in the traditional EEG bands were able to yield Pk>0.8 when discriminating between RSS<5) and (RSS = 5 and/or RSS = 6) and between GAG 0 and GAG 1. However, in order to yield Pk>0.8 when discriminating between RSS<6 and RSS = 6, measures calculated in the traditional EEG bands had to be combined with measures calculated in EEG filtered at high frequencies where the SEMG component is present. In this way, the measures calculated in EEG filtered at high frequencies improved the prediction of unresponsive (RSS<6 and GAG = 0) and responsive (RSS = 6 and GAG = 1) states when different types of stimuli are taken into account.

The use of combination between linear and non-linear EEG measures gave the advantages to deal with both the spectrum and complexity characteristics of the EEG signal. Furthermore, by calculating EEG filtered in high frequency bands, it could be possible to improve the pain responses prediction by including the contribution of the EMG component. In this way, further than the hypnotic effects, also the analgesic effects was better characterized. This can give a strong improvement in the prediction of the response to noxious stimuli in patients under anesthesia and sedation leading to design a method which can be integrated into a medical device for the assessment of pain and nociception during anaesthesia. It was demonstrated that intraoperative monitoring of processed physiological signals reduced anesthetic exposure improving early recovery profiles and faster emergence from anesthesia [75]. Furthermore, it decreased the risk of post-operative delirium and cognitive decline [76]. Hence the outcome will be of benefit for the patients and have a considerable socio-economic impact.

Since the nociceptive stimuli analyzed in the present work are of different kind, our findings might be extended in any kind of surgical procedures, where patients are sedated with both analgesic and hypnotic agents.

However, a limitation of this study can be the use of a database in which only two kind of anesthetics were used (propofol and remifentanil) because it represented a particular case of drug. For a further validation, this method should be also applied to patients undergoing sedation with different drug administrated (i e. sevoflurane)

Conclusions

Measures extracted from EEG filtered at high-frequencies have been proposed as new approach to monitor pain responses during sedation. Traditional measures based on power spectral density and nonlinear measures based on auto-mutual information function (AMIF) applied to EEG filtered in the traditional bands and in high frequency bands improved the discrimination between different sedation levels. Single variables based on nonlinear measures of EEG filtered in VHF band (105–145 Hz) yielded Pk >0.7, Sen>60 and Spe>65 when predicting Ramsey sedation score (RSS) related to between nociceptive responses RSS = 5 and non-responses RSS = 6 to nail bed compression.

The combination of variables based on the spectral power in β and VHF bands, the mean value of the AMIF calculated with q>1 in θ band and the first decay of AMIF calculated with q<1 in VHF (105–145 Hz) band yielded Pk>0.75 in all RSS and GAG prediction.

The obtained results indicate that measures from frontal EEG filtered in high frequencies that contain also EMG components helped to improve the prediction of different stimuli responses. The combination of linear and non-linear measures of EEG filtered in the traditional bands and in higher frequencies resulted to be a promising methodology for the non-invasive prediction of pain responses during sedation. This might give a contribution to solve the problems related to the development of a clinical index able to assess the sedation level.

Glossary

  • BIS: Bispectral index
  • FD(Re02)VHF: First decay (FD) of AMIF using Rényi entropy (Re) with control parameter q = 0.2 in the VHF frequency band
  • FD(Re05)VHF: First decay (FD) of AMIF using Rényi entropy (Re) with control parameter q = 0.5 in the VHF frequency band
  • FD(Re2)δ: First decay (FD) of AMIF using Rényi entropy (Re) with control parameter q = 2 in the δ frequency band
  • FD(Sh)β: First decay (FD) of AMIF using Shannon entropy (Sh) in the β frequency band
  • m(Re05)α : Mean (m) of AMIF using Rényi entropy (Re) with control parameter q = 0.5 in the α frequency band
  • m(Re30)δ: Mean (m) of AMIF using Rényi entropy (Re) with control parameter q = 30 in the δ frequency band
  • m(Re50)θ: Mean (m) of AMIF using Rényi entropy (Re) with control parameter q = 50 in the θ frequency band
  • maxL(Re02)α: First relative maximum (maxL) of AMIF using Rényi entropy (Re) with control parameter q = 0.2 in the α frequency band
  • maxL(Re10)α: First relative maximum (maxL) of AMIF using Rényi entropy (Re) with control parameter q = 10 in the α frequency band
  • maxL(Re2)HF: First relative maximum (maxL) of AMIF using Rényi entropy (Re) with control parameter q = 2 in the HF frequency band
  • maxL(Re2)VHF: First relative maximum (maxL) of AMIF using Rényi entropy (Re) with control parameter q = 2 in the VHF frequency band
  • maxL(Re2)θ: First relative maximum (maxL) of AMIF using Rényi entropy (Re) with control parameter q = 2 in the θ frequency band
  • min2(Re30) δ: Absolute minimum (min2) of AMIF using Rényi entropy (Re) with control parameter q = 30 in the δ frequency band
  • mFα: Weighted mean frequency (mF) in α frequency band
  • Pα: Spectral power in α frequency band
  • Pβ: Spectral power in β frequency band
  • PVHF: Spectral power in VHF frequency band
  • Pθ: Spectral power in θ frequency band

Acknowledgments

This work was supported within the framework of the CICYT grant TEC2013 N0438649, the Research Fellowship Grant FPU AP2009-0858 from the Spanish Government, the End of Residency Award of Hospital CLINIC de Barcelona (XB) and the FIS (Fondo de Investigaciones Sanitarias, Health Department, Government of Spain) grants n° PI/050072 and PS09/01209 (PLG). CIBER of Bioengineering, Biomaterials and Nanomedicine is an initiative of ISCIII.

Author Contributions

Conceived and designed the experiments: PG EJ UM PC MV XB. Performed the experiments: PG EJ XB. Analyzed the data: UM MV. Contributed reagents/materials/analysis tools: PG EJ JFV MJ UM. Wrote the paper: UM MV PC PG.

References

  1. 1. Bouillon TW. Pharmacodynamic interaction between propofol and remifentanil regarding hypnosis, tolerance of laryngoscopy, bispectral index, and electroencephalographic approximate entropy. Anesthesiology. 2004; 100: 1353–1372. pmid:15166553
  2. 2. Xiaoli L, Duan L, Zhenhu L, Voss L, Sleigh JW Analysis of depth of anesthesia with Hilbert–Huang spectral entropy. Clinical Neurophysiology. 2008; 119: 2465–2475. pmid:18812265
  3. 3. Ferenets R, Vanluchene A, Lipping T, Heyse B, Struys MM. Behavior of entropy/complexity measures of the electroencephalogram during propofol-induced sedation: dose-dependent effects of remifentanil. Anesthesiology. 2007; 106: 696–706. pmid:17413907
  4. 4. Gifania P, Rabieea HR, Hashemib MH, Taslimia P, Ghanbari M. Optimal fractal-scaling analysis of human EEG dynamic for depth of anesthesia quantification. Journal of the Franklin Institute. 2007; 344: 212–229.
  5. 5. Jospin M, Caminal P, Jensen EW, Litvan H, Vallverdú M, Struys MM, et al. Detrended fluctuation analysis of EEG as a measure of depth of anesthesia. IEEE Transactions on Biomedical Engineering. 2007; 54: 840–846. pmid:17518280
  6. 6. Rampil I J A primer for EEG signal processing in anesthesia. Anesthesiology. 1998; 89: 980–1002. pmid:9778016
  7. 7. Kreuer S, Biedler A, Larsen R, Schoth S, Altmann S, Wilhelm W. The Narcotrend–a new EEG monitor designed to measure the depth of anaesthesia A comparison with bispectral index monitoring during propofol-remifentanil-anaesthesia. Der Anaesthesist. 2001; 50: 921–925. pmid:11824075
  8. 8. Sigl JC, Chamoun NG. An introduction to bispectral analysis for the EEG. J. Clin. Monit.. 1994; 10: 392–404. pmid:7836975
  9. 9. Viertiö-Oja H, Maja V, Särkelä M, Talja P, Tenkanen N, Tolvanen-Laakso , et al. Description of the Entropy algorithm as applied in the Datex-Ohmeda S/5 Entropy Module. Acta Anaesthesiol. Scand. 2004; 48: 154–161. pmid:14995936
  10. 10. Jensen E W, Lindholm P and Henneberg S. Auto Regressive Modeling with Exogenous Input of auditory evoked potentials to produce an on-line depth of anaesthesia index. Methods of Information in Medicine. 1996; 35: 256–260. pmid:8952311
  11. 11. Litvan H, Jensen E W, Galan J, Lund J, Rodriguez BE, Henneberg SW, et al. Comparison of conventional averaged and rapid averaged, autoregressive-based extracted auditory evoked potentials for monitoring the hypnotic level during propofol induction. Anesthesiology. 2002; 97: 351–358. pmid:12151924
  12. 12. Valencia JF, Borrat X, Gambus PL. Validation of a new index, qcon, for assessment of the level of consciousness during sedation ASA Annual Meeting, Washington, DC, US, October 13–17 2012 Abstract A640.
  13. 13. Luginbuhl M. Stimulation induced variability of pulse plethysmography does not discriminate responsiveness to intubation. Br.J.Anaesth. 2006; 96: 323–329. pmid:16415316
  14. 14. Rantanen M. Novel multiparameter approach for measurement of nociception at skin incision during general anaesthesia. Br. J. Anaesth.. 2006; 96: 367–376. pmid:16431883
  15. 15. Storm H. Changes in skin conductance as a tool to monitor nociceptive stimulation and pain. Current Opinion in Anaesthesiology. 2008; 21: 796–804. pmid:18997532
  16. 16. Jeanne M, Logier R, De Jonckheere J, Tavernier B. Validation of a graphic measurement of heart rate variability to assess analgesia/nociception balance during general anesthesia Proc. IEEE- EMBS Conf. 2009 pp. 1840–1843
  17. 17. Melia U, Vallverdu M, Jospin M, Jensen E W, Valencia J F, Claria F, et al. Prediction of nociceptive responses during sedation by time-frequency representation IEEE-EMBS Proc, Annu Int Conf of the IEEE 2013, pp. 2547–2550
  18. 18. Melia U, Vallverdu M, Jospin M, Jensen E W, Valencia J F, Gambus P, et al. Auto-Mutual Information Function for Predicting Pain Responses in EEG Signals during Sedation XIII Mediterr. Conf on Med and Biol Eng and Comput, 2014, pp. 623–626
  19. 19. Chisholm C J, Zurica J, Mironov D, Sciacca RR, Ornstein E, Heyer EJ. Comparison of electrophysiologic monitors with clinical assessment of level of sedation Mayo Clinic proceedings. Mayo Clinic. 2006; 81: 46–52. pmid:16438478
  20. 20. Ramsay MA, Savege TM, Simpson BR, Goodwin R. Controlled sedation with alphaxalone-alphadolone. Br. Med. J. 1974; 2: 656–659. pmid:4835444
  21. 21. Melia U, Clariá F, Vallverdú M, Caminal P. Filtering and thresholding the analytic signal envelope in order to improve peak and spike noise reduction in EEG signals. Medical engineering & physics. 2014; 36: 547–553.
  22. 22. Plattard D, Soret M, Troccaz J, Vassal P, Giraud Champleboux JY, et al. Patient setup using portal images: 2D/2D image registration using mutual information. Computer Aided Surgery. 2000; 5: 246–262. pmid:11029158
  23. 23. Wells WM III, Viola P and Kikinis R. Multi-modal volume registration by maximization of mutual information. Medical Robotics and Computer Assisted Surgery. 1995; 1: 55–62. pmid:21259415
  24. 24. Hoyer D, Pompe B, Chon KH, Hardraht H, Wicher C, Zwiener U. Mutual information function assesses autonomic information flow of heart rate dynamics at different time scales. IEEE Trans. Biomed. Eng. 2005; 52: 584–592. pmid:15825860
  25. 25. Escudero J, Hornero R, Abasolo D. Interpretation of the auto-mutual information rate of decrease in the context of biomedical signal analysis. Application to electroencephalogram recordings. Physiol. Meas. 2009; 30: 187–199 pmid:19147896
  26. 26. Melia U, Guaita M, Vallverdú M, Embid C, Vilaseca I, Salamero M, et al. 2014 Mutual Information Measures Applied to EEG Signals for Sleepiness Characterization Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2015.01.002
  27. 27. Smith WD, Dutton R, Smith NT. Measuring the performance of anesthetic depth indicators. Anesthesiology. 1996; 84: 38–51 pmid:8572353
  28. 28. Yli-Hankala A, Edmonds HL, Heine MF, Strickland T, Tsueda K. Auditory steady-state response, upper facial EMG, EEG and heart rate as predictors of movement during isoflurane-nitrous oxide anaesthesia. British journal of anaesthesia. 1994; 73: 174–179. pmid:7917731
  29. 29. Chang T, Dworsky W A, White P F Continuous electromyography for monitoring depth of anesthesia Anesth. Analg. 1988; 67: 521–525. pmid:3132056
  30. 30. Poison JS, Watt RC, Kanemoto A. Facial electromyographic monitoring for anesthetic depth assessment. Anesthesiology 1996; 85: A466.
  31. 31. Mathews D M, Clark L, Johansen J, Matute E, Seshagiri CV. Increases in electroencephalogram and electromyogram variability are associated with an increased incidence of intraoperative somatic response. Anesthesia & Analgesia. 2012; 114: 759–770.
  32. 32. Rautee R, Sampson T, Sarkela M, Melto S, Hovilehto S, van Gils M. Application of spectral entropy to EEG and facial EMG frequency bands for the assessment of level of sedation in ICU Engineering in Medicine and Biology Society, 2004. IEMBS'04. 26th Annual International Conference of the IEEE 2004; 2: 3481–3484.
  33. 33. Gugino LD, Chabot RJ, Prichep LS, John ER, Formanek V. Quantitative EEG changes associated with loss and return of consciousness in healthy adult volunteers anaesthetized with propofol or sevoflurane. British Journal of Anaesthesia. 2001; 87: 421–428. pmid:11517126
  34. 34. Feshchenko VA, Veselis RA, Reinsel RA. Propofol-induced alpha rhythm. Neuropsychobiology. 2004; 50: 257–266. pmid:15365226
  35. 35. Hindriks R, van Putten MJ. Meanfield modeling of propofol-induced changes in spontaneous EEG rhythms. Neuroimage. 2002; 60: 2323–2334.
  36. 36. Ching S, Cimenser A, Purdon PL, Brown EN, Kopell NJ. Thalamocortical model for a propofol-induced alpha-rhythm associated with loss of consciousness. Proceedings of the National Academy of Sciences of the United States of America. 2010; 107: 22665–22670. pmid:21149695
  37. 37. Gray CM, McCormick DA. Chattering cells: superficial pyramidal neurons contributing to the generation of synchronous oscillations in the visual cortex. Science. 1996; 274: 109–113. pmid:8810245
  38. 38. McCormick DA, Thierry B. Sleep and arousal: thalamocortical mechanisms. Annual review of neuroscience. 1997; 20: 185–215. pmid:9056712
  39. 39. Velly LJ, Rey MF, Bruder NJ, Gouvitsos FA, Witjas T, Regis JM, et al. Differential dynamic of action on cortical and subcortical structures of anesthetic agents during induction of anesthesia. Anesthesiology. 2007; 107: 202–212. pmid:17667563
  40. 40. Antognini JF, Schwartz K. Exaggerated anesthetic requirements in the preferentially anesthetized brain. Anesthesiology. 1993; 79: 1244–1249. pmid:8267200
  41. 41. Savola MK, Woodley SJ, Maze M and Kendig JJ. Isoflurane and an alpha 2-adrenoceptor agonist suppress nociceptive neurotransmission in neonatal rat spinal cord. Anesthesiology 1991; 75: 489–498. pmid:1716080
  42. 42. Collins JG, Kendig JJ and Mason P. Anesthetic actions within the spinal cord: contributions to the state of general anesthesia Trends Neurosci. 1995; 18: 549–553. pmid:8638296
  43. 43. Gambús PL, Jensen EW, Jospin M, Borrat X, Pallí GM, Fernández-Candil J, et al. Modeling the effect of propofol and remifentanil combinations for sedation-analgesia in endoscopic procedures using an Adaptive Neuro Fuzzy Inference System (ANFIS). Anesthesia & Analgesia. 2011; 112(2): 331–339.
  44. 44. Lapierre CD, Johnson KB, Randall BR, Egan TD. A simulation study of common propofol and propofol-opioid dosing regimens for upper endoscopy: implications on the time course of recovery. Survey of Anesthesiology, 2013; 57(2): 104–105.
  45. 45. Gill M, Green S M, Krauss B. A study of the bispectral index monitor during procedural sedation and analgesia in the emergency department. Annals of emergency medicine. 2003; 41(2): 234–241. pmid:12548274
  46. 46. Chisholm CJ, Zurica J, Mironov D, Sciacca RR, Ornstein E, Heyer EJ. Comparison of electrophysiologic monitors with clinical assessment of level of sedation. In Mayo Clinic Proceedings 2006; 81(1): 46–52.
  47. 47. Andrzejak RG, Lehnertz K, Moormann F, Rieke C, David P, Elger CE. Indications of nonlinear deterministic and finite-dimensional structures in time series of brain electrical activity: dependence on recording region and brain state. Phys Rev. 2001; 64: 061907. pmid:11736210
  48. 48. Stam CJ. Nonlinear dynamical analysis of EEG and MEG: review of an emerging field. Clin Neurophysiol. 2005; 116: 2266–2301. pmid:16115797
  49. 49. Walling PT, Hicks KN. Nonlinear changes in brain dynamics during emergence from sevoflurane anesthesia: preliminary exploration using new software. Anesthesiology. 2006; 105: 927–935. pmid:17065886
  50. 50. Lalitha V, Eswaran C. Automated detection of anesthetic depth levels using chaotic features with artificial neural networks. Journal of medical systems. 2007; 31: 445–452. pmid:18041276
  51. 51. González JR, Vallverdú-Ferrer M, Caminal-Magrans P, Martínez-González F, Roca-Dorda J, Álvarez-Gómez JA. Effects of propofol anesthesia on nonlinear properties of EEG: Lyapunov exponents and short-term predictability. Proc. of 4th European Conference of the International Federation for Medical and Biological Engineering Springer Berlin Heidelberg. 2009; 1272–1275.
  52. 52. Ferenets R, Lipping T, Anier A, Jantti V, Melto S, Hovilehto S. Comparison of entropy and complexity measures for the assessment of depth of sedation IEEE Transactions on Biomedical Engineering. 2006; 53: 1067–1077. pmid:16761834
  53. 53. Becker K, Schneider G, Eder M, Ranft A, Kochs EF, Zieglgänsberger W, et al. Anaesthesia monitoring by recurrence quantification analysis of EEG data. PloS one 2010; 5(1): e8876. pmid:20126649
  54. 54. Acharya UR, Sree SV, Suri JS. Automatic detection of epileptic EEG signals using higher order cumulant features. International journal of neural systems. 2011; 21(05): 403–414.
  55. 55. Jing H, Takigawa M. Topographic analysis of dimension estimates of EEG and filtered rhythms in epileptic patients with complex partial seizures. Biological cybernetics. 2000; 83: 391–397. pmid:11073203
  56. 56. Pereda E, Gamundi A, Rial R, Gonzalez J. Non-linear behaviour of human EEG: fractal exponent versus correlation dimension in awake and sleep stages. Neuroscience letters. 1998; 250: 91–94. pmid:9697926
  57. 57. Eckmann JP, Ruelle D. Fundamental limitations for estimating dimensions and Lyapunov exponents in dynamical systems. Physica D: Nonlinear Phenomena. 1992; 56: 185–187.
  58. 58. Theiler J. Estimating fractal dimension. JOSA A 1990; 7: 1055–1073.
  59. 59. Hoyer D, Friedrich H, Frank B, Pompe B, Baranowski R, Żebrowski JJ, et al. Autonomic information flow improves prognostic impact of task force HRV monitoring. Computer methods and programs in biomedicine. 2006; 81: 246–255. pmid:16483685
  60. 60. Hoyer D, Pompe B, Chon KH, Hardraht H, Wicher C, Zwiener U. Mutual information function assesses autonomic information flow of heart rate dynamics at different time scales. IEEE Trans Biomed Eng. 2005; 52: 584–592. pmid:15825860
  61. 61. Jeong J, Gore JC, Peterson BS. Mutual information analysis of the EEG in patients with Alzheimer’s disease. Clin. Neurophysiol. 2001; 112: 827–835. pmid:11336898
  62. 62. Zikov T, Bibian S, Dumont GA, Huzmezan M, Ries CR. Quantifying cortical activity during general anesthesia using wavelet analysis. IEEE Transactions on Biomedical Engineering, 2006; 53(4): 617–632. pmid:16602568
  63. 63. Huang NE, Shen Z, Long SR, Wu MC, Shih HH, Zheng Q, et al. The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysis P. Roy. Soc. Lond. A Mat. 1998; 454: 903–995.
  64. 64. Rehman N and Mandic DP Multivariate empirical mode decomposition. P. Roy. Soc. Lond. A Mat. 2010; 466: 1291–1302.
  65. 65. Li X, Li D, Liang Z, Voss LJ, Sleigh JW. Analysis of depth of anesthesia with Hilbert–Huang spectral entropy. Clin. Neurophysiol. 2008; 119: 2465–2475. pmid:18812265
  66. 66. Wacker M, Witte H. Time-frequency techniques in biomedical signal analysis. A tutorial review of similarities and differences. Methods Inf. Med. 2013; 52: 279–96. pmid:23703538
  67. 67. Watt RC, Hameroff SR. Phase space electroencephalography (EEG): a new mode of intraoperative EEG analysis. Int J Clin Monitor Comput. 1988; 5: 3–13. pmid:3171345
  68. 68. Bruhn J, Ropcke H, Hoeft A. Approximate entropy as an electroencephalographic measure of anesthetic drug effect during desflurane anesthesia. Anesthesiology. 2000; 92(3): 715–26. pmid:10719951
  69. 69. Magagnin V, Bassani T, Bari V, Turiel M, Maestri R, Pinna GD, et al. Non-stationarities significantly distort short-term spectral, symbolic and entropy heart rate variability indices. Physiological measurement. 2011; 32(11): 1775. pmid:22027399
  70. 70. Cohen BA, Sances AJ. Stationarity of the human electroencephalogram. Medical and Biological Engineering and Computing. 1977; 15(5): 513–518. pmid:199805
  71. 71. Wong K F, Galka A, Yamashita O, Ozaki T. Modeling Non-stationary Variance in EEG Time Series by State Space GARCH. Model Computers in Biology and Medicine. 2006; 36(12): 1327–1335. pmid:16293239
  72. 72. Persson J. Comments on modeling the stationarity and gaussianity of spontaneous electroencephalographic activity stationarity of the human electroencephalogram. IEEE Transactions on Biomedical Engineering. 1977; 24(3): 302. pmid:873559
  73. 73. Kawabata N. Test of statistical stability of the electroencephalogram. Biological cybernetics. 1976; 22(4): 235–238. pmid:953081
  74. 74. Kreuzer M, Kochs EF, Schneider G, Jordan D. Non-stationarity of EEG during wakefulness and anaesthesia: advantages of EEG permutation entropy monitoring. Journal of clinical monitoring and computing. 2014; 1: 1–8.
  75. 75. Leslie K, Myles PS, Chan MT. Risk factors for severe postoperative nausea and vomiting in a randomized trial of nitrous oxide-based vs nitrous oxide-free anaesthesia Br J Anaesth. 2008; 101: 498–505. pmid:18682411
  76. 76. Chan MT, Cheng BC, Lee TM, Gin T. BIS-guided anesthesia decreases postoperative delirium and cognitive decline. Journal of neurosurgical anesthesiology. 2013; 25 (1): 33–42. pmid:23027226