Effect of Topical Anaesthetics on Interstitial Colloid Osmotic Pressure in Human Subcutaneous Tissue Sampled by Wick Technique

  • Hans Jørgen Timm Guthe ,

    hjgu@helse-bergen.no

    Affiliation Department of Paediatrics, Haukeland University Hospital, Bergen, Norway

  • Torbjørn Nedrebø,

    Affiliations Section of Physiology, Department of Biomedicine, University of Bergen, Bergen, Norway, Hyperbaric Medical Unit, Department of Occupational Medicine, Haukeland University Hospital, Bergen, Norway

  • Olav Tenstad,

    Affiliation Section of Physiology, Department of Biomedicine, University of Bergen, Bergen, Norway

  • Helge Wiig,

    Affiliation Section of Physiology, Department of Biomedicine, University of Bergen, Bergen, Norway

  • Ansgar Berg

    Affiliations Department of Paediatrics, Haukeland University Hospital, Bergen, Norway, Section for Paediatrics, Department of Clinical Medicine University of Bergen, Bergen, Norway

Abstract

Objectives

To measure colloid osmotic pressure in interstitial fluid (COPi) from human subcutaneous tissue with the modified wick technique in order to determine influence of topical application of anaesthetics, dry vs. wet wick and implantation time on COPi.

Material and Methods

In 50 healthy volunteers interstitial fluid (IF) was collected by subcutaneous implantation of multi-filamentous nylon wicks. Study subjects were allocated to two groups; one for comparing COPi obtained from dry and saline soaked wicks, and one for comparing COPi from unanaesthetized skin, and skin after application of a eutectic mixture of local anaesthetic (EMLA®, Astra Zeneca) cream. IF was sampled from the skin of the shoulders, and implantation time was 30, 60, 75, 90 and 120 min. Colloid osmotic pressure was measured with a colloid osmometer. Pain assessment during the procedure was compared for EMLA cream and no topical anaesthesia using a visual analogue scale (VAS) in a subgroup of 10 subjects.

Results

There were no significant differences between COPi obtained from dry compared to wet wicks, except that the values after 75 and 90 min. were somewhat higher for the dry wicks. Topical anaesthesia with EMLA cream did not affect COPi values. COPi decreased from 30 to 75 min. of implantation (23.2±4.4 mmHg to 19.6±2.9 mmHg, p = 0.008) and subsequently tended to increase until 120 min. EMLA cream resulted in significant lower VAS score for the procedure.

Conclusion

COPi from subcutaneous tissue was easily obtained and fluid harvesting was well tolerated when topical anaesthetic was used. The difference in COPi assessed by dry and wet wicks between 75 min. and 90 min. of implantation was in accordance with previous reports. The use of topical analgesia did not influence COPi and topical analgesia may make the wick technique more acceptable for subjects who dislike technical procedures, including children.

Trial Registration

ClinicalTrials.gov NCT01044979

Introduction

Oedema formation is characterized by accumulation of fluid within the interstitial space and is a result of increased transcapillary fluid flux and/or decreased lymphatic drainage as described for more than 100 years ago by Starling [1] and later quantitatively expressed by the equation [2]: (1)Jv denotes net transcapillary filtration and CFC refers to the capillary filtration coefficient, which is defined as the net filtration in 100 g tissue per minute for each mmHg rise in net capillary filtration pressure. Pc and Pi are the hydrostatic pressure in the capillaries and interstitial fluid (IF), respectively. COPp and COPi are the colloid osmotic pressures of plasma and IF, and σ is the capillary wall reflection coefficient for plasma proteins. In view of the relations described in the Starling equation, increasing CFC or ▵P can increase fluid flux across the microvascular wall.

The extra vascular forces are smaller than the intravascular pressures, but still important determinants of capillary exchange. Plasma and interstitial colloid osmotic pressure (COP) are therefore essential parameters for understanding fluid exchange during oedema formation and fluid therapy. Sampling of IF by the wick method was first described by Aukland and Fadnes [3] and has been extensively evaluated in animal models [4] [5] [6] [7]. Recently, different groups of patients with fluid disturbances have been studied and have provided important novel data for the understanding and treatment of various disease processes [8] [9] [10]. Some methodological work has been performed in volunteers, with the assumption that similar correlations occur in healthy humans [11] [12].

Implantation of wicks in adults is usually done after intradermal injections of a local anaesthetic, and we know from pilot studies that without local anaesthetic, the wick insertion causes some pain and discomfort. To our knowledge, there are no data regarding COPi in children, mainly because this patient group has not been available for such non-therapeutic research. Minimizing both unpleasant and distressing procedures and trauma from physical and emotional pain is obligate when a paediatric population is involved in clinical research [13]. In order to apply the wick technique for sampling of IF in children it is therefore important to examine how the application of topical anaesthetics on the skin affects the measured values of COP in the IF.

The aim of this study was therefore to evaluate whether topical application of anaesthetics affects measured values of COPi. In addition we wanted to examine whether measured COPi is different when IF is obtained from dry or saline soaked wicks and to validate optimal wick implantation time in healthy humans.

Materials and Methods

Ethics Statement

The protocol for this study was approved by the local ethics committee (Regional Committee for Medical and Health Research Ethics, Western-Norway) at the Department of Paediatrics, Haukeland University Hospital, where all human experimentation was conducted. Participants were continuously recruited from the clinical staff after simple enquiry. Written informed consent was obtained from all participants involved in the study.

The wick method

Sampling of IF for determination of COPi and protein distribution were achieved by means of multifilamentous nylon wicks with a diameter of about 0.8 mm (Polyamid no. 8, Norsk Fletteri AS, Bergen, Norway) sewn into subcutaneous tissue. All wicks were sterilized by gamma irradiation (Institute for Energy Technology, Kjeller, Norway). Double threaded wicks were placed on straight sterile suture needles (Acufirm, 210/3, Germany) and tied with a knot at the end. The skin was disinfected with a solution of 0.5% chlorhexidine before inserting the wick in lengths of approximately 5 cm. Except for the knot, ends protruding from the skin were cut of, leaving the knot with 0.5 cm of wick on the outside. Adhesive plastic film (Tegaderm, 3 M Canada Inc.) was placed over both ends of the wick in order to reduce evaporation of fluid. All wicks were placed in parallel, and with a distance of at least 1 cm to each other. At the end of the implantation period, the central part of each wick was rapidly transferred to separate mineral oil filled centrifuge tubes with funnel. Heavily blood stained wicks (judged visually) were discarded and blood stained parts of wicks were cut off if possible. Wicks were centrifuged for 10 minutes at 14.000 rpm and wick fluid could then be collected at the bottom of the tube because the plastic funnel held back the wick during centrifugation. All samples were frozen in plastic tubes (Sarstedt, Reagiergefaße, micro tubes, 1.5 ml) at −20°C until analysis. All procedures were performed under sterile conditions.

Before analysis, room tempered samples were transferred by pipette to a glass capillary tube. The capillary tube was sealed in one end with plasticine (Haematocrit sealing compound, No.74950; BRAND, Germany) and centrifuged in a haematocrit centrifuge (SABA, Haematocrit 20, Hettich) for 3 min. in order to separate mineral oil from wick fluid.

Colloid osmotic pressure measurements

COP was measured directly with a semi permeable membrane transducer colloid osmometer designed for small fluid samples [14] [15]. The reference camber was filled with isotonic saline (NaCl 9 mg/ml) and a membrane impermeable for molecules greater than a molecular weight of 30-kDalton (PM-30 Amicron, Lexington, MA, USA) was used. Registration of negative hydrostatic pressure, when samples were put on top of the membrane, was measured by a pressure transducer, amplified and recorded (Easy Graph P930, Gould Inc., USA). Before analysing samples the colloid osmometer was calibrated hydrostatically with a saline filled column representing a pressure of 20 mmHg. In order to verify membrane response and to test the accuracy of the whole system, a solution of serum with a known colloid osmotic pressure (COPc) was used as a standard reference. After flushing the sample chamber 4 times, 2 µl saline was left for recording zero pressure. Both saline, serum and wick fluid were sucked up by a soft absorbing tissue paper.

High performance liquid chromatography (HPLC)

In order to determine the distribution of macromolecules in the IF and plasma, a high-resolution size exclusion chromatography using a 4.6 mm (ID)×30 cm TosoHaas Super Sw3000 (Tosoh Biosciences, Stuttgart, Germany) with an optimal separation range for globular proteins of 10–500 kDa was used. One µl of isolated plasma or wick fluid was diluted in 49 µl HPLC buffer to a total volume of 50 µl, and 5 µl of this solution was injected onto the column using an A-905 auto sampler connected to an Ettan 900 LC System (GE Healthcare, formerly Amersham Biosciences). The column was eluted at a constant flow of 0.35 ml/min (P-905 pump) with a 0.1 mM phosphate buffer (pH 6.7) containing 0.1 mM Na2SO4. Proteins were measured by UV detection at 210 nm using an UV-900 monitor and a 0.7 µl flow cell (path length of 3 mm) connected directly to the column outlet. The HPLC-system was operated by a unicorn software module (ver. 4.12).

Experimental design

The study was designed as a non-blinded, sequential descriptive study. The study population was enrolled between March 2008 and September 2010.

Effect of equilibration time.

In order to compare equilibrium time for dry and saline soaked wicks, four dry nylon wicks were inserted subcutaneously into one upper arm and four saline soaked wicks into the contra lateral upper arm in 20 subjects. Thereby, each subject served as his/her own control. Implantation time was 30, 60, 90 and 120 min. on both sides. Ten additional subjects had 3 wicks implanted for 60, 75 and 90 min. respectively.

Effect of topical anaesthetics.

In order to study a possible effect of topical anaesthetics on the COPi measurements saline soaked wicks were used in 20 subjects. Saline soaked wicks are commonly used in human studies [16] [17] [18] [19] [20] [21] [22] [23] [24] [25] and from our own pilot studies, they cause less pain than dry wicks during insertion. Four wicks were inserted subcutaneously in the same position on each upper arm. On the test arm 2.5 grams EMLA cream was applied and covered with an occlusive dressing for 60 minutes prior to insertion of the wicks (1 gram equals a narrow strip that is 38 mm×5 mm wide containing lidocaine 2.5%/prilocaine 2.5%). Placebo cream was not applied on the control arm before insertion of the wick. During insertion, ten research subjects graded pain on a visual analogue scale (VAS).

A venous blood sample of 5 ml was obtained from all participants after the wicks had been inserted. After the blood had clotted, serum was separated from the sample by centrifugation, 3000 rpm for 10 min. The plasma was immediately frozen in plastic tubes (Sarstedt, Reagiergefaße, micro tubes, 1.5 ml) at −20°C.

Statistical analysis.

Two tailed paired t-tests were used for comparison of different groups. All values are presented as mean ± one standard deviation (SD), and a p-value<0.05 was considered significant. SigmaPlot 11 (Sy Stat Software/Inc.; Germany) was used for data analyses.

Results

Patients

The study population consisted of fifty healthy volunteers, 36 males and 14 females with mean age 36.4±5.9 years (range 29–58) and mean weight of 77.5 kg. There were no complications to wick implantation or blood sampling.

Wick fluid content and function of colloid osmometer

The average wick length of 5 cm gave nearly 4 µl wick fluid after centrifugation. Two µl was used to measure colloid osmotic pressure, hence duplicate measurements were not possible. Each COP measurement took approximately 4 min. and was performed at laboratory temperatures of 20–22°C. COPC before testing patient IF showed a mean COPC of 27.3±1.5 mmHg (n = 77) with a variance of 2.2.

Blood contamination of wicks

From a total of 380 inserted wicks, 95 (22%) were discarded because of visible blood. The proportion of blood stained wicks was similar for wicks inserted without and with topical anaesthesia (23% vs. 21%) An additional 9.2% of the wicks had insufficient fluid content for analysis. Blood contamination occurred less frequently in subjects who only had three wicks inserted subcutaneously (13%). Sixty-six% of accepted wicks were classified as light pink, and the proportion of clear wicks was higher in the group receiving topical anaesthesia vs. no anaesthesia (83% vs. 71%).

Measurement of plasma colloid osmotic pressure

Mean COPp for all subjects was 27.6±1.8 mmHg (range 23.8–31.8).

Effect of equilibration time

COPi in interstitial fluid isolated from dry and wet wicks at the different sampling times are shown in Fig. 1. For both dry and wet wicks COPi declined through the first 75 min. after implantation and subsequently increased slightly, but statistically not significantly until all were removed after 120 min. For dry wicks, mean COPi in the same tissue decreased from 25.9±4.4 mmHg after 30 min. of implantation to 21.1±1.5 mmHg after 75 min. (p = 0.043). At 120 min. the mean value was 23.7±5.0 mmHg (p>0.05 from nadir at 75 min.). A similar pattern was seen for wet wicks (21.0±3.2 mmHg at 30 min. vs. 18.7±3.0 mmHg at 75 min. (p>0.05) and 23.2±4.8 mmHg at 120 min (p>0.05) compared to 75 min.) Both dry and wet wicks reached an equilibrium level of 23 mmHg between 75 and 120 min.

thumbnail
Figure 1. Colloid osmotic pressure and implantation time.

Colloid osmotic pressure in interstitial fluid collected from wicks after various times of implantation. Significant difference (p<0.05) between dry (•) and wet (▪) wicks at 30 min. are indicated with () and between dry wicks from 30 to 75 min. with ().

https://doi.org/10.1371/journal.pone.0031332.g001

Effect of topical anaesthetics

There were no significant differences between COPi from wet wicks implanted without or after application of a topical anaesthetic at any of the implantation times (Figure 2). After anaesthesia COPi slowly increased from 19.3±2.8 mmHg at 30 min. to 21.9±4.4 mmHg at 120 min. while the corresponding figures without anaesthesia were 20.9±4.4 mmHg and 20.8±4.3 mmHg (figure 2).

thumbnail
Figure 2. Topical anaesthesia and colloid osmotic pressure.

Colloid osmotic pressure in interstitial fluid collected from wet wicks inserted without (•) or after topical anaesthesia with EMLA (▴) plotted against duration of insertion. Mean COPi was 21.0 mmHg in the group without and 20.6 mmHg in the group with EMLA. No significant differences were found between the groups.

https://doi.org/10.1371/journal.pone.0031332.g002

A significant lower VAS score was found comparing wick insertion with EMLA and no topical anaesthesia (4.2 vs. 5.8, p<0.0049) in a subgroup of 10 subjects.

HPLC of isolated fluid/extravasation of plasma proteins

The size distribution of proteins in fluids isolated from dry and saline soaked wicks and plasma were determined by HPLC. Representative elution patterns are shown in Fig. 3. Protein peaks in plasma corresponded to that of fluids from dry and wet wicks, and the elution pattern was similar in that the globulin peaks were higher than that of albumin. Except for a small haemoglobin peak, which was usually seen in samples from IF, no low molecular weight contaminants were detected.

thumbnail
Figure 3. Distribution of macromolecules in interstitial fluid.

High resolution size exclusion chromatography of plasma (black line) and interstitial fluid derived from: A; dry (red line) or wet (blue line) wicks, B; wet wicks with (red line) or without (blue line) topical anaesthetics. Wicks were collected after 60 min. of implantation. Ordinate: Absorption units at UV 210 normalized to the highest peak (HSA). Retention time for human serum albumin (HSA), IgG and alpha 2 macroglobulin (α2M) standards indicated. A small haemoglobin peak between 11 and 12 min. retention was usually seen in interstitial fluid.

https://doi.org/10.1371/journal.pone.0031332.g003

Discussion

The transmural colloid osmotic pressure plays major roles in the control of fluid transport across the capillary endothelium and provides important information when fluid is administrated to patients. COPi will significantly influence the transcapillary fluid flux under normal and diseased states [26]. However, the usefulness of measuring COP in clinical practice is still limited due to lack of simple and reliable methods, and discomfort during implantation and removal of wicks. In this study we show that COPi from subcutaneous tissue is easily obtained and that fluid harvesting is well tolerated when topical anaesthetic is used. Most importantly, the use of a topical anaesthetic did not alter the ease of IF harvesting or COPi values when using the wick method for sampling.

To our knowledge, there are few studies of sampling IF without the use of injected local anaesthetics, and the use of topical lidocaine/prilocaine cream prior to wick insertion has not previously been evaluated. In a study by Poulsen et al, one participant had 3 out of 19 wicks inserted without any anaesthesia, with equal results as the mean of all wicks in the same person [27]. EMLA cream, which contains lidocaine and prilocaine, is a low cost topical anaesthetic. It has been found to give equally effective dermal analgesia when assessed with VAS and verbal rating scales (VRS) for venous puncture in children [28] and in adults [29]. The analgesic effect is not affected by skin pigmentation [30]. EMLA cream can be applied from birth (gestational age >37 weeks) and has proven safe and effective in decreasing pain response to venous puncture in neonates in combination with oral sucrose [31]. Intradermal or subcutaneous injection of lidocaine will give almost instant local anaesthesia, but has the disadvantage of an extra uncomfortable skin puncture. In the present study the use of EMLA cream reduced the pain associated with the implantation of wicks as judged from a lower VAS-score. No adverse effects were observed, except that a mild and transient local paleness or redness was observed in some patients. Local injections of different concentrations of lidocaine and prilocaine have shown variable vasoactive responses, although prilocaine has vasodilator properties [32]. Skin reflectance spectroscopy and laser Doppler blood flowmetry show a biphasic skin-blood-flow response with initial vasoconstriction followed by vasodilatation after 3 hours of EMLA cream occlusion [33]. Comparison of vein diameter by Doppler colour ultrasound using EMLA cream or amethocaine indicates a capillary constrictor response rather than venous dilatation [34]. Our results show that despite small variations in skin colour, COPi obtained from wet wicks throughout the implantation time was not significantly affected by the use of EMLA cream indicating that only minor changes in local microcirculation and transudation of fluid occurred across the capillary membrane. Although the manufacturer recommends application of EMLA cream on intact skin for at least 60 min. before procedures [35], and prolongation to 120 min. does not seem to have additional efficacy [30], longer application than 60 min. may contribute to a more pronounced vasoconstriction. Its effect on COPi will presumably be of minor importance since both vasoconstriction and vasodilatation is rapidly reversed after removal of EMLA cream.

Sampling of IF by subcutaneous wicks may cause tissue and vessel damage with subsequent local inflammation and bleeding resulting in increasing capillary permeability to proteins and increased COPi. We experienced more frequent bleeding than reported in previous studies [11] [9] where injections of anaesthetic agents were used. One possible explanation may be that a small deposition of liquid can influence local haemostasis with less bleeding as a consequence. Blood stained wicks were discarded in accordance with the recommendations of Aukland & Fadnes [3]. In this study it was reported that a haemoglobin concentration less than 0.2 g/dl in clear and pink wicks [3], indicating a maximum increase in total wick fluid protein content of only 5% as long as the wick was not clearly blood stained. HPLC indicates a low haemoglobin contamination in sampled IF confirming a well operating colloid osmometer. Normal plasma COP in humans is 25–30 mmHg and our findings agree well with this [26].

Subcutaneous implantation of wicks in the upper arm region represents the approximate level of the heart, and variations in body position will only have limited influence on COPp and COPi [12]. All study persons participated in daily activity before and after implanting the wicks. As in previous studies we experienced fluctuations in COPp that were probably due to individual differences within the study population, but were also modestly related to low COPp and low COPi. This association was more pronounced after 90 and 120 min. of implantation.

The working mechanism of implanted wicks has been carefully evaluated by Wiig et al where true COPi is best obtained by the crossover method, and optimal implantation time for wicks is believed to be between 90 and 120 minutes in rat models [5]. We found a slow, but statistically non-significant increase in COPi for IF collected from both dry and wet wicks between 75 and 120 min. after insertion which may be ascribed to local inflammation due to mechanical tissue trauma, similar to what has been described in earlier studies on healthy humans [11]. Implantation for longer than 120 min. seems to increase protein concentration in wick fluid from local inflammation with extravasation of plasma proteins [3]. In normally hydrated subcutaneous tissue COPi in wick fluid is found in the range 12.3–18.8 mmHg on the thorax and reduced to 6.5–13.0 below waist level (ankle) [12] [24]. Prolonged horizontal positioning before implantation results in a modest increase in COPi. The finding of a higher mean COPi in all our subjects compared to other studies of healthy humans may be due to longer transfer time of wicks from subcutaneous tissue too mineral oil filed tubes. However, this seems unlikely because implantation of wicks was done according to protocol in all subjects as in previous studies in our lab.

The present study has some limitations. In order to optimize evaluation of topical anaesthesia, the subjects as well as the investigator should ideally have been blinded to which arm EMLA cream was applied. Blinding of the investigator would have been possible, but blinding of participants was difficult because EMLA cream is known to create a sensation of numbness. Since there is a tradition of using locally injected anaesthetics in wick studies, future studies should compare injection and topical administration of local anaesthesia before wick insertion.

In conclusion, sampling of IF by wicks in adults was less painful after application of topical EMLA cream than without local anaesthesia. EMLA cream had no significant influence on COPi. The COP values obtained in the present study using wick technique were similar to reference data obtained with other sampling methods. Our results indicate an optimal wick implantation time between 75–90 min. Since topical anaesthesia did not affect COP measurements, it is possible to extend the usefulness of the wick method, especially in subjects who dislike technical procedures, including children.

Acknowledgments

We want to thank Trond Markestad for valuable and helpful comments on the manuscript.

Author Contributions

Conceived and designed the experiments: HJG AB HW. Performed the experiments: HJG OT AB HW. Analyzed the data: HJG TN OT AB. Contributed reagents/materials/analysis tools: HW OT HJG AB TN. Wrote the paper: HJG AB.

References

  1. 1. Starling EH (1896) On the Absorption of Fluids from the Connective Tissue Spaces. J Physiol (Lond) 19: 312–326.
  2. 2. Fadnes HO, Reed RK, Aukland K (1978) Mechanisms regulating interstitial fluid volume. Lymphology 11: 165–169.
  3. 3. Aukland K, Fadnes HO (1973) Protein concentration of interstitial fluid collected from rat skin by a wick method. Acta Physiol Scand 88: 350–358.
  4. 4. Fadnes H, Aukland K (1977) Protein concentration and colloid osmotic pressure of interstitial fluid collected by the wick technicue: Analysis and evaluation of the method. Microvascular Research 14: 11–25.
  5. 5. Wiig H, Heir S, Aukland K (1988) Colloid osmotic pressure of interstitial fluid in rat subcutis and skeletal muscle: comparison of various wick sampling techniques. Acta Physiol Scand 133: 167–175.
  6. 6. Kramer GC, Sibley L, Aukland K, Renkin EM (1986) Wick sampling of interstitial fluid in rat skin: further analysis and modifications of the method. Microvascular Research 32: 39–49.
  7. 7. Heltne JK, Husby P, Koller ME, Lund T (1998) Sampling of interstitial fluid and measurement of colloid osmotic pressure (COPi) in pigs: evaluation of the wick method. Lab Anim 32: 439–445.
  8. 8. Tollan A, Oian P, Fadnes HO, Maltau JM (1993) Evidence for altered transcapillary fluid balance in women with the premenstrual syndrome. Acta Obstet Gynecol Scand 72: 238–242.
  9. 9. Noddeland H, Riisnes SM, Fadnes HO (1982) Interstitial fluid colloid osmotic and hydrostatic pressures in subcutaneous tissue of patients with nephrotic syndrome. Scand J Clin Lab Invest 42: 139–146.
  10. 10. Khiabani HZ, Anvar MD, Kroese AJ, Stranden E (2000) Transcapillary forces and the development of oedema in the lower limb of patients with chronic critical limb ischaemia (CLI). Eur J Vasc Endovasc Surg 19: 598–604.
  11. 11. Noddeland H (1982) Colloid osmotic pressure of human subcutaneous interstitial fluid sampled by nylon wicks: evaluation of the method. Scand J Clin Lab Invest 42: 123–130.
  12. 12. Noddeland H (1982) Influence of body posture on transcapillary pressures in human subcutaneous tissue. Scand J Clin Lab Invest 42: 131–138.
  13. 13. European Union (2008) Ethical considerations for clinical trials on medicinal products conducted with the paediatric population. Eur J Health Law 15: 223–250.
  14. 14. Aukland K, Johnsen HM (1974) A colloid osmometer for small fluid samples. Acta Physiol Scand 90: 485–490.
  15. 15. Wiig H, Halleland EG, Fjaertoft M, Aukland K (1988) Measurement of colloid osmotic pressure in submicrolitre samples. Acta Physiol Scand 132: 445–452.
  16. 16. Oian P, Maltau JM, Noddeland H, Fadnes HO (1986) Transcapillary fluid balance in pre-eclampsia. Br J Obstet Gynaecol 93: 235–239.
  17. 17. Oian P, Maltau JM, Noddeland H, Fadnes HO (1985) Oedema-preventing mechanisms in subcutaneous tissue of normal pregnant women. Br J Obstet Gynaecol 92: 1113–1119.
  18. 18. Stranden E, Myhre HO (1983) Transcapillary forces in patients with lower limb ischemia. Scand J Clin Lab Invest 43: 233–239.
  19. 19. Noddeland H, Omvik P, Lund-Johansen P, Ofstad J, Aukland K (1984) Interstitial colloid osmotic and hydrostatic pressures in human subcutaneous tissue during early stages of heart failure. Clin Physiol 4: 283–297.
  20. 20. Koomans HA, Kortlandt W, Geers AB, Dorhout Mees EJ (1985) Lowered protein content of tissue fluid in patients with the nephrotic syndrome: observations during disease and recovery. Nephron 40: 391–395.
  21. 21. Haaverstad R, Romslo I, Larsen S, Myhre HO (1996) Protein concentration of subcutaneous interstitial fluid in the human leg. A comparison between the wick technique and the blister suction technique. Int J Microcirc Clin Exp 16: 111–117.
  22. 22. Semb KA, Aamdal S, Oian P (1998) Capillary protein leak syndrome appears to explain fluid retention in cancer patients who receive docetaxel treatment. J Clin Oncol 16: 3426–3432.
  23. 23. Heradstveit BE, Guttormsen AB, Langorgen J, Hammersborg SM, Wentzel-Larsen T, et al. (2010) Capillary leakage in post-cardiac arrest survivors during therapeutic hypothermia - a prospective, randomised study. Scand J Trauma Resusc Emerg Med 18: 29.
  24. 24. Bates DO, Levick JR, Mortimer PS (1994) Starling pressures in the human arm and their alteration in postmastectomy oedema. J Physiol 477(Pt 2): 355–363.
  25. 25. Bates DO, Levick JR, Mortimer PS (1993) Change in macromolecular composition of interstitial fluid from swollen arms after breast cancer treatment, and its implications. Clin Sci (Lond) 85: 737–746.
  26. 26. Aukland K, Reed RK (1993) Interstitial-lymphatic mechanisms in the control of extracellular fluid volume. Physiol Rev 73: 1–78.
  27. 27. Poulsen HL (1973) Subcutaneous interstitial fluid albumin concentration in long-term diabetes mellitus. Scand J Clin Lab Invest 32: 167–173.
  28. 28. Nilsson A, Boman I, Wallin B, Rotstein A (1994) The EMLA patch–a new type of local anaesthetic application for dermal analgesia in children. Anaesthesia 49: 70–72.
  29. 29. Shaikh FM, Naqvi SA, Grace PA (2009) The influence of a eutectic mixture of lidocaine and prilocaine on minor surgical procedures: a randomized controlled double-blind trial. Dermatol Surg 35: 948–951.
  30. 30. Riendeau LA, Bennett D, Black-Noller G, Fan L, Scavone JM (1999) Evaluation of the analgesic efficacy of EMLA cream in volunteers with differing skin pigmentation undergoing venipuncture. Reg Anesth Pain Med 24: 165–169.
  31. 31. Abad F, Diaz-Gomez NM, Domenech E, Gonzalez D, Robayna M, et al. (2001) Oral sucrose compares favourably with lidocaine-prilocaine cream for pain relief during venepuncture in neonates. Acta Paediatr 90: 160–165.
  32. 32. Willatts DG, Reynolds F (1985) Comparison of the vasoactivity of amide and ester local anaesthetics. An intradermal study. Br J Anaesth 57: 1006–1011.
  33. 33. Bjerring P, Andersen PH, Arendt-Nielsen L (1989) Vascular response of human skin after analgesia with EMLA cream. Br J Anaesth 63: 655–660.
  34. 34. Ashley EM, Quick DG, El-Behesey B, Bromley LM (1999) A comparison of the vasodilatation produced by two topical anaesthetics. Anaesthesia 54: 466–469.
  35. 35. AstraZeneca (2005) Emla Cream product information. Available: http://www1.astrazeneca-us.com/pi/EMLA.pdf. Accessed 2012 Jan 11.